Abstract: High-throughput liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) methodology for the determination of methamphetamine (METH), amphetamine (AMP), 4-hydroxymethamphetamine (4-OH-METH), and 4-hydroxyamphetamine (4-OH-AMP) was developed and validated using simple trichloroacetic acid sample treatment. The method was validated in rat serum, brain, and testis. Lower limits-of-quantitation (LOQ) for METH and AMP were 1 ng • mL − 1 using positive ion electrospray tandem mass spectrometry (MS/M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
30
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 49 publications
0
30
0
Order By: Relevance
“…Determination of METH and AMP concentration in rat serum was based on the liquid-liquid phase extraction (LLE) method developed by Hendrickson et al (2006). In brief, 25 or 50 l of each serum sample was diluted to 100 l using drug-free normal rat serum (Pel-Freez Biologicals, Rogers, AR).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Determination of METH and AMP concentration in rat serum was based on the liquid-liquid phase extraction (LLE) method developed by Hendrickson et al (2006). In brief, 25 or 50 l of each serum sample was diluted to 100 l using drug-free normal rat serum (Pel-Freez Biologicals, Rogers, AR).…”
Section: Methodsmentioning
confidence: 99%
“…The drug-containing solutions from LLE were injected (20 l) onto a 3-m BDS Hypersil C8 column (Thermo Fisher Scientific) and analytically separated using a binary linear gradient (Hendrickson et al, 2006). The flow rate was 0.3 ml/min.…”
Section: Methodsmentioning
confidence: 99%
“…Serum samples were prepared as described above and stored at Ϫ20°C until analyzed. PCP was extracted from serum by liquidphase extraction, using a simple trichloroacetic acid treatment as described previously for METH (Hendrickson et al, 2006). PCP concentrations (ng/ml) in serum samples were determined by liquid chromatography with tandem mass spectrometry detection (LC-MS/ MS), as described previously (Hendrickson et al, 2005).…”
Section: Methodsmentioning
confidence: 99%
“…METH and AMP serum concentrations were determined using LC-MS/MS methodology published previously (Hendrickson et al 2006). A Waters Alliance 2690 HPLC system coupled to a Micromass Quattro LC triple quadrupole mass spectrometer (Waters Corp, Beverly MA) was used for LC-MS/MS analysis.…”
Section: Lc-ms/ms Of Meth Amp and 4-hydroxylated Metabolites In Serummentioning
confidence: 99%