2013
DOI: 10.1167/iovs.12-11490
|View full text |Cite|
|
Sign up to set email alerts
|

Quantitative Fundus Autofluorescence in Mice: Correlation With HPLC Quantitation of RPE Lipofuscin and Measurement of Retina Outer Nuclear Layer Thickness

Abstract: Citation: Sparrow JR, Blonska A, Flynn E, et al. Quantitative fundus autofluorescence in mice: correlation with HPLC quantitation of RPE lipofuscin and measurement of retina outer nuclear layer thickness. Invest Ophthalmol Vis Sci. 2013;54:281254: -282054: . DOI:10.1167 PURPOSE. Our study was conducted to establish procedures and protocols for quantitative autofluorescence (qAF) measurements in mice, and to report changes in qAF, A2E bisretinoid concentration, and outer nuclear layer (ONL) thickness in mice of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

6
87
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 65 publications
(93 citation statements)
references
References 40 publications
6
87
0
Order By: Relevance
“…For example, A2E levels in the vitamin E-treated mice were 54% higher (P < 0.05). Similarly, noninvasive in vivo measurement of RPE lipofuscin by quantitative fundus autofluorescence (qAF) analysis (16), revealed higher levels of fundus autofluorescence in mice treated with vitamin E from age 1-8 mo (P < 0.05) (Fig. 4C).…”
Section: Accumulation Of Bisretinoid In Dark-and Light-reared Albino mentioning
confidence: 80%
See 3 more Smart Citations
“…For example, A2E levels in the vitamin E-treated mice were 54% higher (P < 0.05). Similarly, noninvasive in vivo measurement of RPE lipofuscin by quantitative fundus autofluorescence (qAF) analysis (16), revealed higher levels of fundus autofluorescence in mice treated with vitamin E from age 1-8 mo (P < 0.05) (Fig. 4C).…”
Section: Accumulation Of Bisretinoid In Dark-and Light-reared Albino mentioning
confidence: 80%
“…Quantitative Fundus Autofluorescence. Images were acquired and analyzed as previously described (16).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Detector sensitivity was set between 80 and 100 to avoid pixel saturation. Nine successive frames were acquired in high-speed mode (8.9 images/s) and a 55°field, and frames were aligned, averaged, and saved in non-normalized mode (Sparrow et al, 2013).…”
Section: Mouse Lines and Husbandry Pde6bmentioning
confidence: 99%