Quantitative urine amino acid analysis using liquid chromatography tandem mass spectrometry and aTRAQ® reagents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
55
1
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 71 publications
(61 citation statements)
references
References 15 publications
1
55
1
1
Order By: Relevance
“…Therefore, all further results have been back calculated against this external calibration curve, which was reanalyzed twice before each run. Additionally, opting for this quantification way helps to decrease the batch-to-batch variability (Held et al 2011). …”
Section: Internal Versus External Calibrationmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, all further results have been back calculated against this external calibration curve, which was reanalyzed twice before each run. Additionally, opting for this quantification way helps to decrease the batch-to-batch variability (Held et al 2011). …”
Section: Internal Versus External Calibrationmentioning
confidence: 99%
“…Nowadays, identification and quantification of amino acids by mass spectrometry are rather uncommon in clinical laboratories. Only a few methods have already been developed and validated and are based either on native (Piraud et al 2003(Piraud et al , 2005Waterval et al 2009) or on derivatized (Dettmer et al 2012;Dietzen et al 2008;Harder et al 2011;Held et al 2011) metabolites identification.…”
Section: Introductionmentioning
confidence: 99%
“…This method allows detection of both ASA and ASA anhydrides without any need for further sample preparation, even at very low concentrations which would be undetectable by traditional IEC. Additionally, we reviewed 5 years (2009-13) of IEC results obtained by our clinical laboratory to evaluate the need for increased sensitivity and specificity for this analyte.Briefly, 45 amino acids and related compounds were labeled using the aTraq™ reagents from AB Sciex [12][13][14]; the chromatographic separation was obtained using ABSciex amino acid analysis column (C18, 4.6 × 150 mm, 5 μm); the LC-MS/MS system was an API 4000 tandem Clinica Chimica Acta 442 (2015) 73-74 http://dx. …”
mentioning
confidence: 99%
“…Briefly, 45 amino acids and related compounds were labeled using the aTraq™ reagents from AB Sciex [12][13][14]; the chromatographic separation was obtained using ABSciex amino acid analysis column (C18, 4.6 × 150 mm, 5 μm); the LC-MS/MS system was an API 4000 tandem Clinica Chimica Acta 442 (2015) 73-74 http://dx.…”