Quorum Sensing vs Quorum Quenching: A Battle With No End in Sight 2014
DOI: 10.1007/978-81-322-1982-8_16
|View full text |Cite
|
Sign up to set email alerts
|

Quorum Sensing Biosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…The reporter protein may be detected optically or electrochemically; for example, the measurement of an amount of the protein luciferase encoded by lux gene can be quantified via bioluminescence. QS biosensors serve as fast and reliable tools for detecting specific or various types of autoinductors (Wynendaele et al 2013;O'Connor et al 2015;Rai et al 2015). Examples of methods based on biosensors are listed below (Table 1).To detect AHLs, mutants of bacteria strains that naturally produce bioluminescence in response to AHL molecules may also be used.…”
Section: Measurement Of Ai Productionmentioning
confidence: 99%
“…The reporter protein may be detected optically or electrochemically; for example, the measurement of an amount of the protein luciferase encoded by lux gene can be quantified via bioluminescence. QS biosensors serve as fast and reliable tools for detecting specific or various types of autoinductors (Wynendaele et al 2013;O'Connor et al 2015;Rai et al 2015). Examples of methods based on biosensors are listed below (Table 1).To detect AHLs, mutants of bacteria strains that naturally produce bioluminescence in response to AHL molecules may also be used.…”
Section: Measurement Of Ai Productionmentioning
confidence: 99%
“…Detection of quorum sensing molecules is often performed by using quorum sensing reporter bacteria strains, of which most are sensitive to either autoinducer-1 (AHL's) or autoinducer-2 (Steindler and Venturi, 2007 ; Rai et al, 2015 ). As mentioned previously, these bacterial reporters can be based on non-genetically modified or genetically-modified bacteria.…”
Section: Analytical Techniquesmentioning
confidence: 99%
“…Since the C. violaceum -based biosensor plate assay presented some limitations, such as a high detection threshold and an inability to detect any 3-hydroxy-substituted AHLs [ 52 ], HPLC-MS analysis of the supernatants of the four strains cultured in MB was performed. The production of AHL was confirmed in all bacterial strains ( Table 1 ).…”
Section: Resultsmentioning
confidence: 99%