2012
DOI: 10.2967/jnumed.112.106138
|View full text |Cite
|
Sign up to set email alerts
|

RADAR Reference Adult, Pediatric, and Pregnant Female Phantom Series for Internal and External Dosimetry

Abstract: A new generation of reference computational phantoms, based on image-based models tied to the reference masses defined by the International Commission on Radiological Protection (ICRP) for dose calculations, is presented. Methods Anatomic models based on nonuniform rational b-spline modeling techniques were used to define reference male and female adults, 15-y-olds, 10-y-olds, 5-y-olds, 1-y-olds, newborns, and pregnant women at 3 stages of gestation, using the defined reference organ masses in ICRP publicatio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
49
0
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 78 publications
(53 citation statements)
references
References 22 publications
2
49
0
2
Order By: Relevance
“…The present study sought to establish new standard fetal doses from 18 F-FDG administration during pregnancy, using realistic voxel-based anthropomorphic phantoms (16). The value found in early pregnancy (2.5E-2 mGy/MBq) is comparable to the current standard value (2.2E-2 mGy/MBq) estimated from monkey data (2).…”
Section: Discussionsupporting
confidence: 50%
See 2 more Smart Citations
“…The present study sought to establish new standard fetal doses from 18 F-FDG administration during pregnancy, using realistic voxel-based anthropomorphic phantoms (16). The value found in early pregnancy (2.5E-2 mGy/MBq) is comparable to the current standard value (2.2E-2 mGy/MBq) estimated from monkey data (2).…”
Section: Discussionsupporting
confidence: 50%
“…By contrast, the fetuses of the first and second trimester are significantly smaller in the new phantoms (85 and 1,114 g, compared with 458 and 1,642 g, respectively), and thus the doses were higher (170% and 135%, respectively). Dose differences are also partly explained by the different disposition of the organs inside the voxel-based phantoms, which tend to be more closely associated than those in the old phantoms (16).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to standardize all external and internal dosages, a new generation of models is under development using standardized software for internal dose calculations based on the dose estimates for radiopharmaceuticals (12).…”
Section:  Cytologymentioning
confidence: 99%
“…Voxelized phantoms, [16][17][18] which are based on segmented patient data, provide a realistic anatomy; however, their voxelized nature limits anatomical variations and motion. Hybrid phantoms [19][20][21][22][23][24] combine the advantages of voxelized and mathematical phantoms: they are based on segmented patient data to create a realistic anthropomorphic anatomy, and use nonuniform rational B-spline (NURBS) surfaces and polygon meshes to define each anatomical object, so that organ variations and movement are easily performed with rigid and nonrigid transformations. However, due to the time-consuming process of development, the number of existing hybrid phantoms is limited, most modeling adults with few pediatric anatomies.…”
Section: Introductionmentioning
confidence: 99%