2005
DOI: 10.1016/j.echo.2005.01.031
|View full text |Cite
|
Sign up to set email alerts
|

Radial Strain Gradient Across the Normal Myocardial Wall in Open-chest Pigs Measured with Doppler Strain Rate Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
29
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(31 citation statements)
references
References 27 publications
2
29
0
Order By: Relevance
“…25 The short axis images of the anterior wall, only, were analyzed with 4 elliptically shaped ROI's with size 2 Â 6 mm and SL 2 mm as well as 2 elliptically shaped ROI's with size 4 Â 6 mm and SL 4 mm. Using a ROI of 6 mm across the beam enables averaging over several ultrasound beams in the lateral direction.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…25 The short axis images of the anterior wall, only, were analyzed with 4 elliptically shaped ROI's with size 2 Â 6 mm and SL 2 mm as well as 2 elliptically shaped ROI's with size 4 Â 6 mm and SL 4 mm. Using a ROI of 6 mm across the beam enables averaging over several ultrasound beams in the lateral direction.…”
Section: Discussionmentioning
confidence: 99%
“…After premedication with ketamine/atropine, anesthesia was induced and maintained with loading doses and continuous infusions of fentanyl, midazolam, pancuronium and pentobarbital as previously described in detail. 25,26 The animals undervent tracheotomy and intubation; ventilation was continued with a mixture of N 2 O (56e57%) and oxygen. Fluid substitution was given as 15 mL kg h À1 of Ringer's Acetate with 20 mmol L À1 KCl added.…”
Section: Experimental Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…Because the frame rate was 96 -102 frames/s, the step size for integration was 9.8 -10.4 ms. Next, strain is obtained by evaluating the change of distance between pairs of two points defined on all pixels on the image by utilizing the displacement values. The distance of all two-pixel pairs at the initial time frame is equivalent to "L 0" on the above equation and set at 3 mm in this study (17). The initial time frame is set at end diastole to evaluate contraction; in other words "deformation" of the myocardium occurring in systole.…”
Section: Methodsmentioning
confidence: 99%
“…Volumes were indexed (normalised) for body surface area (BSA) calculated as BSA = k BW 2/3 /100 where BW is body weight in kg and k for pigs is 9 m 2 kg À2/3 [13]. Tissue velocity images were transferred to a work station, converted to strain rate images (SRI) and analysed for strain with commercially available software (EchoPacPC, GE Vingmed Ultrasound, Horten, Norway) as described earlier [14]. Radial peak ejection and postsystolic strain was calculated in the subendo and subepicardial halves of the anterior left ventricular wall with aortic valve opening and closure defined from pulsed wave Doppler recordings.…”
Section: Data Acquisitionmentioning
confidence: 99%