2016
DOI: 10.1016/j.measurement.2016.03.071
|View full text |Cite
|
Sign up to set email alerts
|

Radiated noise analysis via human body for intra-body communication

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…A comprehensive noise analysis for capacitive IBC was reported by researchers from several Japanese institutions [13,14,56,133,180,[183][184][185]. They showed that IBC systems are affected by large common-mode noise from various kinds of electronic equipment in living spaces, such as lighting devices, air conditioners, liquid crystal televisions, and refrigerators [13,14].…”
Section: Sources Of Artifacts and Noise In Ibcmentioning
confidence: 99%
See 1 more Smart Citation
“…A comprehensive noise analysis for capacitive IBC was reported by researchers from several Japanese institutions [13,14,56,133,180,[183][184][185]. They showed that IBC systems are affected by large common-mode noise from various kinds of electronic equipment in living spaces, such as lighting devices, air conditioners, liquid crystal televisions, and refrigerators [13,14].…”
Section: Sources Of Artifacts and Noise In Ibcmentioning
confidence: 99%
“…An effective way of improving impedance balance and reducing common-mode noise in the system was connecting an additional electrode or a compact capacitor to a ground electrode, according to [13,14] (Figure 13). Two types of noise, excluding transceivers noise, are coupled to the embedded receiver [183]: radiated noise via human body [133,183,184] and conducted noise via floor ground [180]. Noisy-channel models of a capacitive IBC system with an embedded receiver situated in the vicinity of a wall was investigated by Sasaki et al in [180].…”
Section: Sources Of Artifacts and Noise In Ibcmentioning
confidence: 99%
“…Privacy issues [ 30 , 31 ], ISM band saturation, power loss, and interferences with medical equipment and patient health [ 32 , 33 , 34 ] are some of the reasons that recommend the use of the so-called Intra Body Communications (IBC) [ 35 ]. Previous proposals have studied the propagation of RF signals [ 36 , 37 ], capacitive [ 38 , 39 , 40 ] and galvanic coupling [ 41 , 42 ] and even ultrasonic [ 43 , 44 ] emissions through the human tissues.…”
Section: Related Workmentioning
confidence: 99%
“…Most studies concerning common-mode noise do not really consider random signals but interfering signals that originate in the electromagnetic environment as in [4] or on common-mode signals that are part of the sensed measurands as in [5]. However, analog integrated circuits have circuit topologies where some components contribute common-mode electronic noise.…”
Section: Introductionmentioning
confidence: 99%