Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography

Abstract: Selection of the most appropriate imaging modality should be performed in view of the delivered doses, required image quality and information and the clinical circumstances.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
185
3
23

Year Published

2007
2007
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 348 publications
(215 citation statements)
references
References 14 publications
4
185
3
23
Order By: Relevance
“…CBCT has a fairly low radiation dosage compared with other advanced radiographic methods, 25,26 and the amount of radiation could be considered similar to that of eight panoramic radiographs. 36 The ''Malmgren index'' 35 was originally adopted for use with intraoral periapical radiography.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…CBCT has a fairly low radiation dosage compared with other advanced radiographic methods, 25,26 and the amount of radiation could be considered similar to that of eight panoramic radiographs. 36 The ''Malmgren index'' 35 was originally adopted for use with intraoral periapical radiography.…”
Section: Discussionmentioning
confidence: 99%
“…25,26 The doses vary, however, between different brands, imaging areas, and exposure parameters used. 27,28 Since its introduction, the CBCT technique has gained widespread use in various fields of dentistry, not least in orthodontics.…”
Section: Introductionmentioning
confidence: 99%
“…In comparison, standard panoramic radiography delivers ϳ13.3 Sv and multidetector CT with a similar FOV delivers ϳ860 Sv. 26,27 Image quality can vary considerably with dose; images acquired with higher radiation exposure often produce superior image quality.…”
Section: Dentomaxillofacial Imagingmentioning
confidence: 99%
“…In comparison, standard panoramic radiography delivers ϳ13.3 Sv and multidetector CT with a similar FOV delivers ϳ860 Sv. 26,27 Image quality can vary considerably with dose; images acquired with higher radiation exposure often produce superior image quality.The discussion below reviews potential CBCT applications in the dentomaxillofacial regions. Most of this research remains preliminary; further prospective and outcomes-based research is required to make informed recommendations on the appropriate use of CBCT in dentomaxillofacial imaging.…”
mentioning
confidence: 99%
“…Respective dedicated scanners were initially equipped with image intensifiers; image quality was very limited, the exposure unnecessarily high [45]. Although better results are obtained at lower dose when using standard clinical CT scanners with appropriate scan protocols, the high interest of practitioners in that field led to the installation of hundreds of maxillo-facial scanners all over Europe.…”
Section: Fd-ct For Dedicated Maxillo-facial Scanningmentioning
confidence: 99%