Radiopaque Resorbable Inferior Vena Cava Filter Infused with Gold Nanoparticles

Abstract: Failure to remove a retrievable inferior vena cava (IVC) filter can cause severe complications with high treatment costs. Polydioxanone (PPDO) has been shown to be a good candidate material for resorbable IVC filters. However, PPDO is radioluscent under conventional imaging modalities. Thus, the positioning and integrity of these PPDO filters cannot be monitored by computed tomography (CT) or x-ray. Here we report the development of radiopaque PPDO IVC filters based on gold nanoparticles (AuNPs). Commercially … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
21
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 20 publications
(25 citation statements)
references
References 26 publications
2
21
0
Order By: Relevance
“…TEM and UV-Vis spectrum of 4-nm AuNPs. The transmission electron microscopy (TEM) result (A) is consistent with the ~520 nm peak (shown by the arrow) on the UV-Vis spectrum (B) for the 4-nm AuNPs [4].…”
Section: Figuresupporting
confidence: 54%
See 2 more Smart Citations
“…TEM and UV-Vis spectrum of 4-nm AuNPs. The transmission electron microscopy (TEM) result (A) is consistent with the ~520 nm peak (shown by the arrow) on the UV-Vis spectrum (B) for the 4-nm AuNPs [4].…”
Section: Figuresupporting
confidence: 54%
“…In terms of in vitro cytotoxicity, no cytotoxicity was observed (one-way ANOVA, p<0.05) when evaluated on immortalized human vascular endothelial cell RF24 cells and normal lung fibroblast MRC5. This suggests that no significant difference in cell viability among the treatment groups, or between the treatment groups and the control group (one-way ANOVA, p<0.05) (Figure 3) [4].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…We further improved the contrast agent by using 2- and 4-nm hydrophobic gold nanoparticles. Due to the higher Z number of gold, the radiopacity was even stronger than iodine infused PPDO, and the gold content and radiopacity remained stable over 6 weeks, which is the expected dwell time of the temporary ICVF 101 ( Fig. 8 ).…”
Section: Radiopaque Nanoparticles and Biomaterials For Atherosclerosimentioning
confidence: 81%
“…Our group recently engaged in the development of radiopaque and resorbable infera vena cava filters (IVCFs) 100 , 101 . IVCFs are indicated for at-risk patients who are contraindicated with anticoagulants.…”
Section: Radiopaque Nanoparticles and Biomaterials For Atherosclerosimentioning
confidence: 99%