2022
DOI: 10.1016/j.vibspec.2022.103449
|View full text |Cite
|
Sign up to set email alerts
|

Raman spectroscopic measurement guidelines for carbon isotopic composition of CO2

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 34 publications
1
7
0
Order By: Relevance
“…From Table S3 and Figure 7, the average σ 0 α I =σ α I when changing w CCD from 15 to 5 μm in the simulation is 0.57, which is consistent with the value of 0.58 obtained from Equation (27). Similarly, when changing f from 80 to 160 cm, the mean value of σ 0 α I =σ α I in the simulation is 0.74, which is consistent with the value of 0.71 obtained from Equation (28). Consequently, with reasonable accuracy, Equations ( 25) and ( 26) can predict the relative change in σ α I , which indicates the improvement in σ α I resulting from enhanced instrumental performance.…”
Section: Pixel Resolutionsupporting
confidence: 85%
See 3 more Smart Citations
“…From Table S3 and Figure 7, the average σ 0 α I =σ α I when changing w CCD from 15 to 5 μm in the simulation is 0.57, which is consistent with the value of 0.58 obtained from Equation (27). Similarly, when changing f from 80 to 160 cm, the mean value of σ 0 α I =σ α I in the simulation is 0.74, which is consistent with the value of 0.71 obtained from Equation (28). Consequently, with reasonable accuracy, Equations ( 25) and ( 26) can predict the relative change in σ α I , which indicates the improvement in σ α I resulting from enhanced instrumental performance.…”
Section: Pixel Resolutionsupporting
confidence: 85%
“…Since work reported by Li et al, 24 several σ δ 13 C measurements of CO 2 by Raman spectroscopy with precision below 1‰ have been reported. 22,24,27,28 Achieving precision less than 1‰, even in this study, where Γ w /Δx w is large, requires 13 I þ F:D: more than 10 6 (e À ) (Figure 5). Earlier studies 24,27,28 with smaller Γ w /Δx w require even more 13 I þ F:D: (Equations 22 and 23).…”
Section: Precisionmentioning
confidence: 64%
See 2 more Smart Citations
“…As for the isotope analysis using micro-Raman spectroscopy, five reports of the relevant literature have described carbon isotope analysis of CO2 (Arakawa et al, 2007;Li et al, 2018;Yokokura et al, 2020;Cui et al, 2021;Wang et al, 2022). One report describes nitrogen isotope analysis of N2 (Yamamoto and Hagiwara, 2022).…”
mentioning
confidence: 99%