2021
DOI: 10.1016/j.jphs.2020.11.006
|View full text |Cite
|
Sign up to set email alerts
|

Ramelteon modulates gamma oscillations in the rat primary motor cortex during non-REM sleep

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 17 publications
(18 citation statements)
references
References 48 publications
0
18
0
Order By: Relevance
“…A recording interface assembly was prepared as previously described ( Okada et al, 2016 ; Sasaki et al, 2017 ; Shikano et al, 2018 ; Yoshimoto et al, 2021b ). In short, the assembly was composed of an electrical interface board (EIB; EIB‐36‐PTB, Neuralynx) and custom-made shell and core bodies created by three-dimensional (3-D) printers.…”
Section: Methodsmentioning
confidence: 99%
“…A recording interface assembly was prepared as previously described ( Okada et al, 2016 ; Sasaki et al, 2017 ; Shikano et al, 2018 ; Yoshimoto et al, 2021b ). In short, the assembly was composed of an electrical interface board (EIB; EIB‐36‐PTB, Neuralynx) and custom-made shell and core bodies created by three-dimensional (3-D) printers.…”
Section: Methodsmentioning
confidence: 99%
“…The doses of hypnotics used were based on previous studies in rodents to promote sleep. The half-life in rodents of caffeine is 40–60 min ( Hartmann and Czok, 1980 ), DORA-22 is 37.8 min ( Gotter et al, 2013 ), ramelteon is less than 60 min ( Yoshimoto et al, 2021 ), and zolpidem is about 20 min ( Garrigou-Gadenne et al, 1989 ). Drug treatments were assigned in a paired design (one WT and one Fmr1 KO mouse per treatment group per study group).…”
Section: Methodsmentioning
confidence: 99%
“…Preparation A recording interface assembly was prepared as previously described. [31][32][33] In short, the assembly was composed of an electrical interface board (EIB) (EIB-36-PTB, Neuralynx, Inc., Bozeman, MT, U.S.A.) and shell and core bodies custom-made by a three-dimensional printer. The EIB had a sequence of metal holes for connections with wire electrodes.…”
Section: Ethical Approvalsmentioning
confidence: 99%
“…After we confirmed that depth of anesthesia was adequate, we implanted electrodes for ECGs, EMGs, and ECoGs as previously described. 33,35) Briefly, we placed a rat onto a stereotaxic apparatus (SR-6R-HT, Narishige, Tokyo, Japan). 36) We attached one wire electrode to the left pectoralis muscle to record cardiac signals (ECGs), whereas we implanted another electrode into the trapezius to record myogenic potentials (EMGs).…”
Section: Ethical Approvalsmentioning
confidence: 99%
See 1 more Smart Citation