2020
DOI: 10.1111/jcpe.13271
|View full text |Cite
|
Sign up to set email alerts
|

Randomized controlled clinical trial comparing implant sites augmented with a volume‐stable collagen matrix or an autogenous connective tissue graft: 3‐year data after insertion of reconstructions

Abstract: Aim:To assess mid-term clinical, radiographic and profilometric outcomes at implant sites, previously grafted with a volume-stable collagen matrix (VCMX) or an autogenous subepithelial connective tissue graft (SCTG).Methods: VCMX or SCTG were randomly applied to single implant sites in 20 patients. Following abutment connection and insertion of final reconstructions (baseline), patients were re-examined at 6 months (6M), at 1 year (FU-1) and at 3 years (FU-3). Measurements included the following: clinical data… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
164
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(168 citation statements)
references
References 28 publications
4
164
0
Order By: Relevance
“…Seven studies [ 16 , 17 , 18 , 19 , 20 , 21 , 22 ] fulfilled the inclusion criteria, two of those were classified as Follow-ups [ 17 , 19 ]. We identified 1050 potentially relevant studies through a systematic electronic database search (521 Ovid Medline + 529 WoS All Databases).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Seven studies [ 16 , 17 , 18 , 19 , 20 , 21 , 22 ] fulfilled the inclusion criteria, two of those were classified as Follow-ups [ 17 , 19 ]. We identified 1050 potentially relevant studies through a systematic electronic database search (521 Ovid Medline + 529 WoS All Databases).…”
Section: Resultsmentioning
confidence: 99%
“…The study characteristics and the authors’ conclusions are presented in Table 1 . Different techniques were used to measure the thickness of oral mucosa: two authors measured with CAD/CAM (Computer Aided Design/Computer Aided Manufacturing) manufactured stents and endodontic needles [ 17 , 19 ], three just with endodontic needles [ 16 , 20 , 22 ], one with an ultrasonic device [ 18 ], and one with CBCT-scans with a small field of view [ 21 ] to ensure a high quality picture. The CAD/CAM-made stents had guide channels for the endodontic needles so that the measurements were particularly reproducible.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Of this initial gain, 0.77 mm remained after 24 months pointing to a relative horizontal stability of 49%. Four RCTs from the same research group investigated soft tissue augmentation using Fibro-Gide ® (Geistlich Pharma AG, Wolhusen, Switzerland) [48][49][50][51]. Transmucosal probing revealed an initial gain of 1.7 mm with 35% shrinkage after three months and a horizontal stability of 41% three years after crown insertion.…”
Section: Discussionmentioning
confidence: 99%