2022
DOI: 10.1021/acsestwater.2c00446
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and Simultaneous Quantification of Short- and Ultrashort-Chain Perfluoroalkyl Substances in Water and Wastewater

Abstract: Per-and polyfluoroalkyl substances (PFASs) are a class of chemicals of growing concern. Recently, there has been a shift toward the use of short-and ultrashort-chain PFASs, which are difficult to measure with current analytical methods and rarely included in environment monitoring studies. In this research, we developed and optimized online solid-phase extraction, highperformance liquid chromatography, and electrospray ionization high-resolution mass spectrometry methods for the rapid and simultaneous quantifi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
14
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(18 citation statements)
references
References 72 publications
(180 reference statements)
4
14
0
Order By: Relevance
“…Details on the analytical standard preparation and matrix spike for ultrashort PFCA measurements are included in Tables S14–S16. Despite using separate LCMS analytical methods here, we acknowledge that emerging techniques such as mixed-mode columns containing weak anion exchanges and reverse-phased capabilities could achieve similar results with a single method …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Details on the analytical standard preparation and matrix spike for ultrashort PFCA measurements are included in Tables S14–S16. Despite using separate LCMS analytical methods here, we acknowledge that emerging techniques such as mixed-mode columns containing weak anion exchanges and reverse-phased capabilities could achieve similar results with a single method …”
Section: Methodsmentioning
confidence: 99%
“…A separate method was used to measure ultrashort PFCAs, which was adapted from Taniyasu et al 40 anion exchanges and reverse-phased capabilities could achieve similar results with a single method. 41 ■ RESULTS AND DISCUSSION Integration of a Mass-Labeled Indicator of Precursor Oxidation Efficiency. Water samples collected from landfills and wastewater treatment plants contain dissolved solutes (e.g., dissolved organic matter and reduced metals) that can scavenge • OH generated from the thermolysis of persulfate in the oxidation step of the TOP assay.…”
Section: ■ Introductionmentioning
confidence: 99%
“…We transferred 8 mL of each prepared sample into 10 mL sample vials and spiked them with 20 μL of the isotope-labeled internal standard (ILIS) mixture at a concentration of 100 μg L –1 . Six replicates of all samples were prepared so they could be measured in triplicate at each dilution level by means of two separate previously described LC-HRMS (QExactive hybrid quadrupole-orbitrap, ThermoFisher Scientific) analytical methods , needed to measure ultrashort-, short-, and long-chain PFASs.…”
Section: Methodsmentioning
confidence: 99%
“…We used a reversed-phase chromatography method for analysis of short- and long-chain PFASs and a mixed-mode chromatography method for analysis of ultrashort-chain PFASs . Details on the chromatographic and mass spectrometry experiments along with acquisition parameters of each target PFAS, quality control data, and LOQs are provided in the companion text in the Supporting Information and in Tables S8 through S11.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation