2013
DOI: 10.1039/c2lc41049d
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and specific electrochemical detection of prostate cancer cells using an aperture sensor array

Abstract: A rapid, simple and specific cancer cell counting sensor would allow for early detection and better disease management. We have developed a novel cell counting device that can specifically count 125 prostate cancer cells in both complex media with serum and a mixed cell population containing non-target cells within 15 min. The microfabricated glass chip with exposed gold apertures utilizes the anti-EpCAM antibody to selectively count prostate cancer cells via differential pulse voltammetry. The newly developed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
41
0
1

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
3
1

Relationship

2
7

Authors

Journals

citations
Cited by 55 publications
(44 citation statements)
references
References 20 publications
2
41
0
1
Order By: Relevance
“…Impedanzsensoren wurden für die CTC-Identifizierung benutzt, [31,93] und Voltammetriesensoren sind spezifisch zur Identifizierung von Krebszellen geeignet. [94][95][96][97] Jüngst wurde gezeigt, wie die Aufarbeitung von Vollblut, die Gewinnung von CTCs,d ie Zelllyse und die Analyse der mRNA-Expression mit einem Chip-basierten elektrochemischen Detektor ablaufen kann (Abbildung 6A). [98] Der gesamte Prozess wurde auf einem einzigen integrierten Chip durchgeführt und war innerhalb von 30 Minuten abgeschlossen.…”
Section: Integrierte Molekulare Analyse Von Ctcsunclassified
“…Impedanzsensoren wurden für die CTC-Identifizierung benutzt, [31,93] und Voltammetriesensoren sind spezifisch zur Identifizierung von Krebszellen geeignet. [94][95][96][97] Jüngst wurde gezeigt, wie die Aufarbeitung von Vollblut, die Gewinnung von CTCs,d ie Zelllyse und die Analyse der mRNA-Expression mit einem Chip-basierten elektrochemischen Detektor ablaufen kann (Abbildung 6A). [98] Der gesamte Prozess wurde auf einem einzigen integrierten Chip durchgeführt und war innerhalb von 30 Minuten abgeschlossen.…”
Section: Integrierte Molekulare Analyse Von Ctcsunclassified
“…MPA molecule consisted of a thiol functional group at one end, which provided an excellent affinity to gold, and a carboxylic group at another end, which was suitable for bonding covalently to proteins through peptide bond after an activation procedure. Thiol modification of gold electrode surface for protein immobilization was a well-acknowledged technique (32,33,(36)(37)(38). Typically, 4-8 biosensor were prepared in this immobilization step as a batch for this study.…”
Section: Chemical Immobilization Steps On the Gold Electrode (Aue)mentioning
confidence: 99%
“…41,42 These surfaces could be adapted properly to 'Lab-ona-Chip' or microuidic based systems. 43 On the other hand, decision on the immobilization matrix affects the selectivity of the biosensor for the analysis, signicantly. Herein, aer the successful cell adhesion experiments, NC-8 was applied to create a novel selective platform for the cultivation of folate positive HeLa cells.…”
Section: Electrochemical Studiesmentioning
confidence: 99%