2006
DOI: 10.1016/j.chroma.2006.09.086
|View full text |Cite
|
Sign up to set email alerts
|

Rapid determination of complex mixtures by dual-column gas chromatography with a novel stationary phase combination and spectrometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
31
0
1

Year Published

2007
2007
2019
2019

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 57 publications
(32 citation statements)
references
References 44 publications
0
31
0
1
Order By: Relevance
“…Figure 4 shows the separation of a 20 component mixture of polyaromatic hydrocarbons and chlorinated pesticides in just over 8 min. Using either a completely or partially crosslinked IL stationary phase column with a standard RTX-1 column in a 2-D GC mode, an enhanced high speed separation of 20 compounds in 150 s was possible [44]. Application to the analysis of organics in headspace above USA currency was made.…”
Section: High Temperature and Crosslinked Ils As Gc Stationary Phasesmentioning
confidence: 99%
“…Figure 4 shows the separation of a 20 component mixture of polyaromatic hydrocarbons and chlorinated pesticides in just over 8 min. Using either a completely or partially crosslinked IL stationary phase column with a standard RTX-1 column in a 2-D GC mode, an enhanced high speed separation of 20 compounds in 150 s was possible [44]. Application to the analysis of organics in headspace above USA currency was made.…”
Section: High Temperature and Crosslinked Ils As Gc Stationary Phasesmentioning
confidence: 99%
“…Note, if there is any excess silver present the product turns black, then the IL must be resynthesized. The triflate IL columns have been coated using the static coating method at 408C as previously reported [22,25] resulting in a 4 m6100 lm60.08 lm film thickness column. The dication stationary phase 1,9-di(3-vinylimidazolium)nonane triflate will be referred to as the triflate IL column.…”
Section: Column Fabricationmentioning
confidence: 99%
“…Thus, investigation on the chemical structures vs the unique physiochemical properties of organic salts is a hot issue. In particular, bis(imidazolium) salts have been considered as novel solvents and lubricants, 10 ultrastable separation phases, 11,12 and the stationary phases in gas chromatography columns. 7 For some geminal dicationic ionic liquids, the wide range of cation and anion combinations allows various ionic salts.…”
mentioning
confidence: 99%