2020
DOI: 10.1556/1326.2018.00515
|View full text |Cite
|
Sign up to set email alerts
|

Rapid RP-HPLC method for simultaneous estimation of metformin, pioglitazone, and glimepiride in human plasma

Abstract: An isocratic reversed-phase high-performance liquid chromatography (RP-HPLC) method has been developed for rapid and simultaneous separation and estimation of 3 antidiabetic drugs, namely, metformin, pioglitazone, and glimepiride, in human plasma within 3 min. Separation was carried out on a MAGELLEN 5U C18 (5 μm, 150 mm × 4.60 mm) using a mobile phase of MeOH–0.025 M KH2PO4 adjusted to pH 3.20 using ortho-phosphoric acid (85:15, v/v) at ambient temperature. The flow rate was 1 mL/min, and the maximum absorpti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 29 publications
(11 citation statements)
references
References 21 publications
0
11
0
Order By: Relevance
“…The software used for analysis was UV-VIS Analyst. [18][19][20][21][22][23][24][25] The instrument used for the High Performance Liquid Chromatography consisted of binary gradient system. The software used of the HPLC instruments for the method development and the validation purpose was HPLC workstation.…”
Section: Methodsmentioning
confidence: 99%
“…The software used for analysis was UV-VIS Analyst. [18][19][20][21][22][23][24][25] The instrument used for the High Performance Liquid Chromatography consisted of binary gradient system. The software used of the HPLC instruments for the method development and the validation purpose was HPLC workstation.…”
Section: Methodsmentioning
confidence: 99%
“…In addition, REM helps in reducing the body weight and blood pressure in diabetes mellitus patients. [8][9][10] Many analytical methods were illustrated for the estimation of MET from pharmaceutical preparations and plasma by spectroscopic, 11,12 HPLC, [13][14][15] HPLTC, 16 LC-MS, 17,18 and CZE, 19,20 alone and with other drugs. Few analytical procedures were also depicted in the texts for the analysis of REM.…”
Section: -Methyl-4-[[4-(1-methylethoxy)phenyl]methyl]-1-(1-mentioning
confidence: 99%
“…Several methods are illustrated in the literature for the analysis of metformin alone and along with different classes of agents from formulations and body fluids. Recent methods reported were UV-spectrophotometry [ 19 , 20 , 21 ], RP-HPLC [ 22 , 23 , 24 , 25 ], HPTLC [ 24 , 25 ], capillary electrophoresis [ 26 , 27 ] and LCMS [ 28 , 29 , 30 , 31 , 32 ]. There were few reports in the literature for the simultaneous estimation of metformin along with SGLT-2 inhibitors [ 32 , 33 ].…”
Section: Introductionmentioning
confidence: 99%