1998
DOI: 10.1016/s0735-1097(98)80248-9
|View full text |Cite
|
Sign up to set email alerts
|

Rapid three-dimensional echocardiography using rotational geometry: precision and accuracy of left ventricular volumes using various levels of slice resolution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2003
2003
2016
2016

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 0 publications
0
11
0
Order By: Relevance
“…With average rotational geometry, six planes provided accurate estimation of LV volumes and EF. 8,9 Actually, in the present study, accurate determination of LV volumes and EF could be obtained by 3DE using as few as six apical images, including in patients with regions of asynergy. …”
Section: Discussionmentioning
confidence: 72%
See 2 more Smart Citations
“…With average rotational geometry, six planes provided accurate estimation of LV volumes and EF. 8,9 Actually, in the present study, accurate determination of LV volumes and EF could be obtained by 3DE using as few as six apical images, including in patients with regions of asynergy. …”
Section: Discussionmentioning
confidence: 72%
“…Another advantage of this system was its average rotational geometry, which used a small number of apical rotated views. [7][8][9] The average rotational geometry was designed to be fast and simple to be used in clinical situation. An important characteristic of this geometry was that the slice resolution was unchanged along the imaging axis at the same radial distances and was particularly useful for the whole LV.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…This functional information is usually derived from other diagnostic procedures than CT, i.e. echocardiography or projection X-ray ventriculography, despite their limited accuracy and precision compared with MRI [5]. Due to the improved temporal resolution of 83 ms, DSCT can be regarded as a promising method to acquire functional left ventricular parameters as a complementary information that can be a determined from coronary CT angiography datasets non-invasively and without the need for additional contrast agent or radiation exposure [2].…”
Section: Discussionmentioning
confidence: 99%
“…Twodimensional echocardiography (2DE) derived LAV has been shown to provide a more accurate assessment of LA size than M-mode but the problem of geometric assumption still remains [6,7]. Three-dimensional echocardiography (3DE) has demonstrated superior accuracy for measuring left ventricular volume International Journal of Cardiology 123 (2008) 155 -161 www.elsevier.com/locate/ijcard compared to conventional 2DE and the 3DE reconstruction has been validated for LAV quantification [8][9][10]. Real-time 3DE (RT3DE) allows fast acquisition from a single acoustic window of dynamic pyramidal data structure that encompasses the entire heart [11].…”
Section: Introductionmentioning
confidence: 99%