2021
DOI: 10.1016/j.snb.2020.129228
|View full text |Cite
|
Sign up to set email alerts
|

Ratiometric electrochemical analysis on a flexibly-fabricated vibratory electrode module for reliable and selective determination of imidacloprid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 38 publications
0
15
0
Order By: Relevance
“…Chlorpromazine (CPZ) is an antipsychotic drug used to treat psychiatric and personality disorders, and clinical monitoring of CPZ is necessary. Liu et al presented Pt/Co 3 O 4 nanoparticles and methylene blue (MB) monomer-based MIPs for selective detection of CPZ [ 74 ]. Wherein, MB molecule in MIPs provides a fixed internal signal, and the signal of CPZ changes with concentrations, which is a typical on/off ratiometric signal output mode.…”
Section: Applications Of Miecs In Food Safety and Drug Detectionmentioning
confidence: 99%
“…Chlorpromazine (CPZ) is an antipsychotic drug used to treat psychiatric and personality disorders, and clinical monitoring of CPZ is necessary. Liu et al presented Pt/Co 3 O 4 nanoparticles and methylene blue (MB) monomer-based MIPs for selective detection of CPZ [ 74 ]. Wherein, MB molecule in MIPs provides a fixed internal signal, and the signal of CPZ changes with concentrations, which is a typical on/off ratiometric signal output mode.…”
Section: Applications Of Miecs In Food Safety and Drug Detectionmentioning
confidence: 99%
“…For example, Zhang's group reported that the relative standard deviations (RSDs) of single-signal sensor constructed from b-cyclodextrin (b-CD) or prussian blue (PB) is not as low as that of the ratiometric electrochemical sensor constructed based on b-CD and PB for imidacloprid sensing. 7 In addition, they found that the ratiometric electrochemical analysis could also improve the longterm stability of the sensor. Consequently, the ratiometric strategy could effectively reduce the interferences from internal or external factors and improve the robustness and precision of detections.…”
Section: Introductionmentioning
confidence: 99%
“…Hence, the reliability and accuracy of the analysis are improved. 24,25 Metal-organic frameworks (MOFs) are ordered network structures formed by the combination of organic bridging ligands and inorganic metal ions. 26 Numerous studies have demonstrated significant advantages of MOFs in sensing, 27 gas storage, 28 and catalysis 29 ascribed to their porous structure and large specific surface area.…”
Section: Introductionmentioning
confidence: 99%