2023
DOI: 10.1021/acssuschemeng.3c00772
|View full text |Cite
|
Sign up to set email alerts
|

Ratiometric Fluorescent Sensor Based on Hydrogen-Bond Triggering the Internal Filter Effect for Enzyme-Free and Visual Monitoring Pesticide Residues

Abstract: Real-time/field sensing techniques to keep track of methyl parathion (MP) are crucial to human health. In this work, a ratiometric fluorescence probe was constructed by integrating green carbon dots and CdTe quantum dots (CdTe QDs) for highly selective quantitative detection of MP. Under alkaline conditions, MP can be rapidly hydrolyzed to produce pnitrophenol (p-NP); the instantaneous reaction that strengthens the hydrogen bond results in the internal filter effect between the carbon dots and p-NP, which quen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 38 publications
0
6
0
Order By: Relevance
“…This method offers a rapid and convenient approach to creating ratiometric fluorescent probes for environmental contaminant detection. CDs are physically mixed with other reference luminescent materials, such as polymers, nanoparticles, or other fluorophores, to establish a dual-emission system [ 67 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 ] ( Figure 3 a).…”
Section: Construction Strategies Of Cds In Detecting Environmental Co...mentioning
confidence: 99%
See 3 more Smart Citations
“…This method offers a rapid and convenient approach to creating ratiometric fluorescent probes for environmental contaminant detection. CDs are physically mixed with other reference luminescent materials, such as polymers, nanoparticles, or other fluorophores, to establish a dual-emission system [ 67 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 , 94 , 95 , 96 , 97 ] ( Figure 3 a).…”
Section: Construction Strategies Of Cds In Detecting Environmental Co...mentioning
confidence: 99%
“…The fluorescent ratiometric probe exhibits an impressively low detection limit of 4.6 nM. Qin et al [ 88 ] developed a ratiometric fluorescence probe that combines green CDs with CdTe QDs, enabling highly selective and quantitative detection of methyl parathion (MP) ( Figure 3 b,c). Under alkaline conditions, MP undergoes rapid hydrolysis, yielding p-nitrophenol (p-NP).…”
Section: Construction Strategies Of Cds In Detecting Environmental Co...mentioning
confidence: 99%
See 2 more Smart Citations
“…Currently, some interesting fluorescence assays have been reported to detect MP [16,17]. For example, Huang et al [18] constructed a ratiometric fluorescence probe for the AChE activity evaluation and OPs detection via inner filter effect (IFE) of 2,3-diaminophenazine on nitrogen doped carbon dots.…”
Section: Introductionmentioning
confidence: 99%