RBCs labeled at two biotin densities permit simultaneous and repeated measurements of circulating RBC volume

Abstract: Using RBCs labeled with two different densities of biotin, RBC volume can be accurately measured simultaneously and repeatedly in the same subject without radiation exposure.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
52
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 23 publications
(52 citation statements)
references
References 28 publications
0
52
0
Order By: Relevance
“…Advantages include: 1) the biotinylating reagents required are inexpensive and commercially available; 2) the required measurement and synthesis equipment (a flow cytometer and sterile hood) are readily available; and 3) technician time required for analysis is modest (18, 19). Labeling RBCs with biotin, an essential B vitamin, has been shown to be nontoxic (11), and there have been no adverse clinical consequences other than asymptomatic, transient antibody formation in 15 to 20% of adults (20, 21).…”
Section: Discussionmentioning
confidence: 99%
“…Advantages include: 1) the biotinylating reagents required are inexpensive and commercially available; 2) the required measurement and synthesis equipment (a flow cytometer and sterile hood) are readily available; and 3) technician time required for analysis is modest (18, 19). Labeling RBCs with biotin, an essential B vitamin, has been shown to be nontoxic (11), and there have been no adverse clinical consequences other than asymptomatic, transient antibody formation in 15 to 20% of adults (20, 21).…”
Section: Discussionmentioning
confidence: 99%
“…Thus, the distinct RBC subpopulations labeled with different densities of biotin can potentially be used to measure RCV simultaneously or repetitively in the same subject. Because the densities are independently enumerated, no base line correction8 is needed. Such serial measurements would assist in quantitative estimates of erythropoiesis despite the intervening events such as hemmorhage, transfusion, and somatic growth that typically confounds attempts to quantify erythropoiesis in clinical situations.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, the biotin method is practical because 1) the required biotinylation reagents are inexpensive and commercially available, 2) the required instruments (a flow cytometer and sterile hood) are available in most medical center clinical laboratories, and 3) technician time required for analysis is modest 8,9…”
Section: Introductionmentioning
confidence: 99%
“…As long as the peaks representing the fluorescent-labeled BioRBC population(s) remains separate from the unlabeled RBC and from each other, enumeration of the proportion of BioRBC can be accurately determined. Consequently, loss of label does not limit accuracy in determining RCV [5, 6, 55] or RCS under conditions of either normal survival [53] or accelerated removal [50]. …”
Section: Methods For Biotin Rbc Labelingmentioning
confidence: 99%