2011
DOI: 10.1016/j.nucengdes.2011.07.043
|View full text |Cite
|
Sign up to set email alerts
|

Reactor cavity cooling system (Rccs) experimental characterization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
2

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 5 publications
0
8
0
2
Order By: Relevance
“…RDE is an inherently safe nuclear reactor, meaning that the reactor does not need any active safety intervention in the event of a depressurized loss of forced coolant (DLOFC) and pressurized loss of force coolant (PLOFC) [8,9]. The reactor system automatically reverts back to a normal state after the shut-down transient.…”
Section: Theory the Rde Inherent Safetymentioning
confidence: 99%
See 2 more Smart Citations
“…RDE is an inherently safe nuclear reactor, meaning that the reactor does not need any active safety intervention in the event of a depressurized loss of forced coolant (DLOFC) and pressurized loss of force coolant (PLOFC) [8,9]. The reactor system automatically reverts back to a normal state after the shut-down transient.…”
Section: Theory the Rde Inherent Safetymentioning
confidence: 99%
“…The potential for RCCS failure may be greater in D-LOFC events. Failure modes need to be evaluated since long-term loss of the RCCS cooling function could lead to major RPV and cavity damage, and thus lead to a dependence on other less predictable ultimate heat sinks [15].…”
Section: D-lofc Accident In Htgrmentioning
confidence: 99%
See 1 more Smart Citation
“…Hal ini dapat diatasi dengan penambahan pembangkit listrik menggunakan reaktor berpendingin gas helium dengan temperatur tinggi (RGTT). RGTT mempunyai spesifikasi antara lain bahan bakar efisien, limbah nuklir rendah, tahan terhadap penyebaran bahan nuklir berbahaya, energi tahan lama, handal, dan aman dengan adanya reactor cavity cooling system (RCCS) [1][2][3]. Konsep RGTT yang sedang dikembangkan saat ini diberi nama RGTT30 karena didesain dengan daya termal 30 MW th dan temperatur gas helium keluaran teras 700 °C.…”
Section: Pendahuluanunclassified
“…A small-scale experimental facility, with a height of 200 mm, was constructed at Texas A&M University representing a half section of a reactor cavity surrounded by water-cooled standpipes (Capone et al, 2011). Measurements were taken of the external surface temperatures of the vessel and standpipes as well as the axial temperature profile in the cavity.…”
Section: Introductionmentioning
confidence: 99%