2019
DOI: 10.1016/j.coelec.2019.03.015
|View full text |Cite
|
Sign up to set email alerts
|

Real-time absorption spectroelectrochemistry: From solution to monolayer

Abstract: The pioneering work of real-time absorption specroelectrochemistry: a must-read!

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 40 publications
0
7
0
Order By: Relevance
“…Details of the instrumentation can be found elsewhere. 21,22 In short, a threeelectrode cell with GC as the working electrode, Pt as the counter electrode, and Ag/AgNO 3 (0.01 M in 0.1 M TBAPF 6 ACN) as the reference electrode (identical to electrochemical grafting) was employed. The connection between the light source, the electrochemical cell, and the spectrophotometer was ensured through a "Yshaped" optical fiber bundle: 18 fibers to guide the light to the cell and 19 fibers to collect the reflected light from the cell directing it to the CDD detector (320−1080, 0.5 nm spectral resolution, and 2 MHz acquisition bandwidth).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Details of the instrumentation can be found elsewhere. 21,22 In short, a threeelectrode cell with GC as the working electrode, Pt as the counter electrode, and Ag/AgNO 3 (0.01 M in 0.1 M TBAPF 6 ACN) as the reference electrode (identical to electrochemical grafting) was employed. The connection between the light source, the electrochemical cell, and the spectrophotometer was ensured through a "Yshaped" optical fiber bundle: 18 fibers to guide the light to the cell and 19 fibers to collect the reflected light from the cell directing it to the CDD detector (320−1080, 0.5 nm spectral resolution, and 2 MHz acquisition bandwidth).…”
Section: Methodsmentioning
confidence: 99%
“…Details of the instrumentation can be found elsewhere. 21,22 In short, a 3-electrode cell with GC as working electrode, Pt as counter electrode and Ag/AgNO3 (0.01 M in 0.1 M TBAPF6 ACN) as reference electrode (identical to electrochemical grafting) were employed.…”
Section: Spectroelectrochemical Characterizationmentioning
confidence: 99%
“…This highly sensitive home-made measuring bench provides a new perspective to follow the grafting kinetic and get information on the organic layer structuration and its interactions with the supporting substrate. 32 Deposition conditions were varied on carbon and gold to extract new data about the layer structuration.…”
Section: Introductionmentioning
confidence: 99%
“…From this contemporary viewpoint, key concepts and selected contributions over the past 10 years are highlighted. The reader is referred to excellent reviews in the field including those on catalytic applications of MOFs, [28] SEC in the solution state, [29,30] and SEC of adsorbed molecular species relevant to surface-enhanced Raman scattering (SERS), as well as SEC of polymeric thin films for electronics and spintronics, [31] sol-gel films, [32] membranes, sensors, [26] self-assembled monolayers, [33] and even single molecules at an electrochemical interface. [34] In the field of MOF research, which is a focus herein, SEC techniques have received limited attention with only in situ powder X-ray diffraction (PXRD), [35,36] XAS, [37] UV-Vis-NIR, and EPR spectroscopy [38][39][40][41][42][43][44][45] measurements reported to date in the literature.…”
Section: Introductionmentioning
confidence: 99%