2006
DOI: 10.1016/j.saa.2006.01.007
|View full text |Cite
|
Sign up to set email alerts
|

Recalling the appropriate representation of electronic spectra

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
124
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 121 publications
(125 citation statements)
references
References 6 publications
1
124
0
Order By: Relevance
“…This correction by the photon energy dependence is derived from the Einstein coefficients of absorption and spontaneous emission, and it is described in detail elsewhere. 67 In this representation, the spectral intensity is directly proportional to the squared magnitude of the transition dipole moment (TDM) and as a consequence to the Franck−Condon factor. Note that the emission spectra in solution are cut below 12 500 cm −1 (800 nm) because of experimental limitations of the fluorimeter.…”
Section: Methodsmentioning
confidence: 99%
“…This correction by the photon energy dependence is derived from the Einstein coefficients of absorption and spontaneous emission, and it is described in detail elsewhere. 67 In this representation, the spectral intensity is directly proportional to the squared magnitude of the transition dipole moment (TDM) and as a consequence to the Franck−Condon factor. Note that the emission spectra in solution are cut below 12 500 cm −1 (800 nm) because of experimental limitations of the fluorimeter.…”
Section: Methodsmentioning
confidence: 99%
“…The fluorescence spectrum was corrected for the instrument response and multiplied by a factor of l 4 to obtain the spectral shape of the stimulated emission in the time resolved absorption spectra. 41 …”
Section: Methodsmentioning
confidence: 99%
“…10.0 10 3 cm À1 ), implying that the interactionb etween The spectraare plotted in the wavenumber representation, [58] but the wavelengths cale is showno n the top axis for comparison. 10.0 10 3 cm À1 ), implying that the interactionb etween The spectraare plotted in the wavenumber representation, [58] but the wavelengths cale is showno n the top axis for comparison.…”
Section: Steady-state Absorption and Emissionmentioning
confidence: 99%
“…. The spectraare plotted in the wavenumber representation, [58] but the wavelengths cale is showno n the top axis for comparison. Table 1.…”
Section: Steady-state Absorption and Emissionmentioning
confidence: 99%