2023
DOI: 10.1016/j.scitotenv.2022.161361
|View full text |Cite
|
Sign up to set email alerts
|

Recent advances and applicable flexibility potential of electrochemical processes for wastewater treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 55 publications
(9 citation statements)
references
References 144 publications
0
9
0
Order By: Relevance
“…The core findings of this study proved the non-toxic nature of the remediated wastewater produced when EFT was employed. In contrast, Divyapriya et al (2018) investigated the performance of EFT using a ferrocenefunctionalized graphene oxide-based electrode for ciprofloxacin removal under the effect of applied voltage (-0.75 --2.5 V) and solution pH (3)(4)(5)(6)(7)(8)(9). The highest removal efficiency of 99% was obtained at pH 7 and 2 hours of contact time.…”
Section: Electro-fenton Alone For Pollutants Removalmentioning
confidence: 99%
See 3 more Smart Citations
“…The core findings of this study proved the non-toxic nature of the remediated wastewater produced when EFT was employed. In contrast, Divyapriya et al (2018) investigated the performance of EFT using a ferrocenefunctionalized graphene oxide-based electrode for ciprofloxacin removal under the effect of applied voltage (-0.75 --2.5 V) and solution pH (3)(4)(5)(6)(7)(8)(9). The highest removal efficiency of 99% was obtained at pH 7 and 2 hours of contact time.…”
Section: Electro-fenton Alone For Pollutants Removalmentioning
confidence: 99%
“…They found that there was no notable increase in pollutants elimination after the 5 th -cycle of electrode reusability at any conditions of solution pH. He et al (2018) used a (g-C 3 N 4 /ACF) electrode in an electro-Fenton reactor to remove TOC from wastewater under the influence of the reaction time of (0-240 min), current density of (1-4 mA/cm 2 ), and solution pH (2)(3)(4)(5)(6)(7). They attained 91% of TOC removal after 4 hours, 3 mA/cm 2 , and pH 3.…”
Section: Electro-fenton Alone For Pollutants Removalmentioning
confidence: 99%
See 2 more Smart Citations
“…Similarly, processes involving metals such as the electroplating industry generate metal-rich wastewater [ 8 , 9 , 10 ]. The concentration of components creates an environmental pollution crisis, which affects fauna and flora due to the increase in chemical oxygen demand (COD) [ 11 ]. Therefore, wastewater must undergo treatment using available technologies before being discharged into water bodies or soil.…”
mentioning
confidence: 99%