Recent advances in column switching high-performance liquid chromatography for bioanalysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 49 publications
0
5
0
Order By: Relevance
“…Moreover, the backflush mode led to a more stable system, reducing the possibility of void volume formations restoring its initial particles distribution by backwashing the extraction column in every cycle. 26,27…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, the backflush mode led to a more stable system, reducing the possibility of void volume formations restoring its initial particles distribution by backwashing the extraction column in every cycle. 26,27…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, the backflush mode led to a more stable system, reducing the possibility of void volume formations restoring its initial particles distribution by backwashing the extraction column in every cycle. 26,27 The composition of the mobile phase was tested changing the organic proportion from 80% to 95% of methanol. Flow rate was evaluated from 0.2 to 0.6 mL min −1 .…”
Section: Methods Optimizationmentioning
confidence: 99%
“…Using the column-switching approach, the SPE sample preparation technique can be easily combined with a chromatography instrument to provide such an on-line system. This system consists of two high-pressure pumps, an automatic six-port valve, a pre-concentration column, and an analytical column [ 96 ]. On-line SPE cartridges are commonly called pre-columns because the first cartridges used were the same pre-columns used in HPLC to protect analytical columns [ 97 ].…”
Section: Sample Preparationmentioning
confidence: 99%
“…Then, using a six-port valve, the flow direction of the mobile phase is changed to the analytical column, where the chromatographic separation of the analyzed compounds takes place. Elution can be carried out in two different ways, as shown in Figure 11 [ 96 , 100 , 101 ]. In the straight-flush mode, the mobile phase flows in the same direction as in the purge step [ 93 ], while in the back-flush mode, the mobile phase flows in the opposite direction to the purge step [ 91 , 92 , 93 , 95 ].…”