2017
DOI: 10.1016/j.electacta.2017.05.159
|View full text |Cite
|
Sign up to set email alerts
|

Recent Advances in Ion-selective membrane electrodes for in situ environmental water analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
82
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 152 publications
(82 citation statements)
references
References 102 publications
0
82
0
Order By: Relevance
“…76 After inspecting all these papers, it seems clear that the main field of application of nonactin-based ISEs is the detection of NH 4 + in water. Indeed, this fact has been extensively reviewed over the years, e.g., de Marco, 7 Winkler, 77 Crespo, 3 and Cuartero. 1,6 In this context, it is noteworthy to mention the work by de Beer and co-workers that included measuring NH 4 + profiles in freshwater sediments, 78,79 even if those papers were published prior to the established screening time in the present review.…”
Section: Analystmentioning
confidence: 99%
See 1 more Smart Citation
“…76 After inspecting all these papers, it seems clear that the main field of application of nonactin-based ISEs is the detection of NH 4 + in water. Indeed, this fact has been extensively reviewed over the years, e.g., de Marco, 7 Winkler, 77 Crespo, 3 and Cuartero. 1,6 In this context, it is noteworthy to mention the work by de Beer and co-workers that included measuring NH 4 + profiles in freshwater sediments, 78,79 even if those papers were published prior to the established screening time in the present review.…”
Section: Analystmentioning
confidence: 99%
“…Moreover, ISEs are some of the few analytical techniques that provide in situ realtime measurements of the target concentration with total reliability. [1][2][3][4][5] Major examples that evidence the success of ISEs are the membrane-based design of a sensor and have been applied for ion determination mainly in water quality assessment, 1,6,7 clinical analyses, [8][9][10][11] and monitoring of sport practices. 2,[12][13][14] Looking back at the development history of ISEs, the integration of ion-selective membranes (ISMs) as the sensing element has undoubtedly been a disruptive event in this field.…”
Section: Introductionmentioning
confidence: 99%
“…Specifically, nearly 200 papers have been published during the last five years [1]. The advantages of SCISEs over the conventional ion-selective electrodes (ISEs) have been demonstrated in a variety of applications, including medical analysis [2][3][4][5][6], agriculture [7,8], environmental [9][10][11] and water quality monitoring [12][13][14] and process control [15]. Improvements in signal stability, detection limits, reduction of water accumulation at the SC-membrane interphase, transmembrane ion fluxes, reproducibility, and research efforts in the development of new SC materials have been reported [14,[16][17][18][19][20].…”
Section: Introductionmentioning
confidence: 99%
“…Considering these merits, ISEs are getting more attention as routine tools of chemical analysis in industry, clinical and environmental analyses. [22][23][24][25][26] Coated-wire ion-selective electrodes that were employed to overcome the problems associated with conventional ISE's 27,28 still suffer some shortcomings such as giving unreliable measurements due to the fluctuation of the electric potential. 29 New measures must be introduced to the working electrodes to alleviate or eliminate these effects and carbon-paste electrodes (CPE's) 30 appear to be suitable alternatives.…”
Section: Introductionmentioning
confidence: 99%