Recent updates for biomaterials used in total hip arthroplasty

Abstract: BackgroundTotal hip arthroplasty (THA) is probably one of the most successful surgical interventions performed in medicine. Through the revolution of hip arthroplasty by principles of low friction arthroplasty was introduced by Sir John Charnley in 1960s. Thereafter, new bearing materials, fixation methods, and new designs has been improved. The main concern regarding failure of THA has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
84
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 135 publications
(84 citation statements)
references
References 125 publications
0
84
0
Order By: Relevance
“…Hypersensitivity reactions to debris generated from zirconia ceramic wear are likely multifactorial [3,34,54]. With an aging population that is living longer, THA is very common [8,15,34]. Zirconia exposure and sensitization may increase as indications for ceramic-on-polyethylene THA now includes a population that is more active and requiring THA at earlier ages [8,15,55].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Hypersensitivity reactions to debris generated from zirconia ceramic wear are likely multifactorial [3,34,54]. With an aging population that is living longer, THA is very common [8,15,34]. Zirconia exposure and sensitization may increase as indications for ceramic-on-polyethylene THA now includes a population that is more active and requiring THA at earlier ages [8,15,55].…”
Section: Resultsmentioning
confidence: 99%
“…With an aging population that is living longer, THA is very common [8,15,34]. Zirconia exposure and sensitization may increase as indications for ceramic-on-polyethylene THA now includes a population that is more active and requiring THA at earlier ages [8,15,55]. Until clinically validated preimplant and postimplant tests are available to determine the risk of hypersensitivity, it remains important to conduct a complete workup and to consider the diagnosis of a zirconia-induced hypersensitivity reaction.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…19,20 In the last 10 years, a great number of failure reports involving polymeric pieces in arthroplasty applications have been published. 10,21,22 The main factor behind this is described as oxidative degradation of the material, induced by sterilization processes. [22][23][24][25] Overall, sterilization processes remain a major problem when it comes to the use of polymeric materials in biomedical applications, since the employed energy induces rapid aging, oxidation and other surface phenomena that lead to materials fragilization.…”
Section: Introductionmentioning