2020
DOI: 10.1016/j.asmr.2020.01.004
|View full text |Cite
|
Sign up to set email alerts
|

Redesigning Metal Interference Screws Can Improve Ease of Insertion While Maintaining Fixation of Soft-Tissue Anterior Cruciate Ligament Reconstruction Grafts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(13 citation statements)
references
References 27 publications
0
13
0
Order By: Relevance
“…These studies evaluated what kind of impact the type of clamp had on the measurement [ 35 39 , 41 46 , 48 53 , 55 57 , 59 66 , 68 – 82 , 84 87 , 89 , 90 , 92 96 , 98 , 99 , 101 104 , 106 111 , 113 117 ].A variety of clamps for use during the endurance test of tendons were categorized according to the temperature used during the measurement. The clamps are divided into three groups: room temperature clamps [ 61 , 106 , 107 ] [ 35 , 37 39 , 41 , 44 46 , 48 , 49 , 51 53 , 55 57 , 59 , 62 , 64 , 70 , 72 , 75 , 77 80 , 84 , 85 , 87 , 89 , 90 , 92 94 , 96 , 98 , 99 , 101 103 , 109 111 , 115 117 ], cooled clamps (under room temperature with ice, cooled air, d...…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…These studies evaluated what kind of impact the type of clamp had on the measurement [ 35 39 , 41 46 , 48 53 , 55 57 , 59 66 , 68 – 82 , 84 87 , 89 , 90 , 92 96 , 98 , 99 , 101 104 , 106 111 , 113 117 ].A variety of clamps for use during the endurance test of tendons were categorized according to the temperature used during the measurement. The clamps are divided into three groups: room temperature clamps [ 61 , 106 , 107 ] [ 35 , 37 39 , 41 , 44 46 , 48 , 49 , 51 53 , 55 57 , 59 , 62 , 64 , 70 , 72 , 75 , 77 80 , 84 , 85 , 87 , 89 , 90 , 92 94 , 96 , 98 , 99 , 101 103 , 109 111 , 115 117 ], cooled clamps (under room temperature with ice, cooled air, d...…”
Section: Resultsmentioning
confidence: 99%
“… How valuable is the research? Overall quality assessment Aeberhard 2019 [ 35 ] 1 1 1 1 1 1 1 1 1 1 high Aguila 2016 [ 36 ] 1 1 1 2 1 1 1 1 1 1 high Athwal 2020 [ 37 ] 1 1 1 1 1 1 1 1 1 1 high Awogni 2014 [ 38 ] 1 1 1 1 1 1 1 1 1 1 high Aynardi 2017 [ 39 ] 1 1 1 1 1 1 1 1 1 1 high Azar 2009 [ …”
Section: Methodsmentioning
confidence: 99%
“…The pitch and pitch depth parameters may not be a major factor influencing the fixation strengths since magnesium only had a pitch depth difference of 0.175 mm compared to the polymer screw but had significantly higher fixation strength. Moreover, the use of the same screw design with a modification of the tip significantly affected the fixation performance [ 11 ], implying the importance of the tip portion of the screw as well as the importance of its body slope. The shape of the polymer IS had a higher slope profile from the head to the tip of the screw than the magnesium screw; however, at the screw head, they shared the same diameter of 9 mm ( Figure 2 ).…”
Section: Discussionmentioning
confidence: 99%
“…The results found differences in fixation performance, but they were not statistically significant [ 10 ]. However, Athwal et al showed that screw tip design has an influence on the fixation performance [ 11 ], and the study of the IS body slope showed that it also influenced the fixation strength [ 12 ]. The use of a permanent metal IS has some disadvantages, including graft damage, tunnel widening, imaging modalities, required implant removal surgery, and increased difficulty in revision surgeries [ 5 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation