2015
DOI: 10.1109/tia.2014.2347237
|View full text |Cite
|
Sign up to set email alerts
|

Reducing Arc Flash Incident Energy Level in an Offshore Gas Production Unit Using Intelligent Electronic Devices—A Case Study

Abstract: This paper evaluates the protection system of an offshore gas production unit and proposes utilization of devices dedicated to identify the arc flash incidents inside the panels. A quantitative analysis has been performed by comparing the incident energy levels of the original design with the levels provided by the new design. The new design includes numerical relays equipped with dual sensing of arc flash: optical detection of the light and high-speed overcurrent detection. The analysis indicates that a drast… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 4 publications
0
1
0
Order By: Relevance
“…The IED is connected to the measurement equipment that may be current/ voltage or other electrical parameter sensed from mixed line. Similar concepts are also introduced for an offshore gas production proving the feasibility of utilising IED-based numerical relay for overcurrent detection [15]. These methods detect a travelling wave (peak width of the travelling wave, rise time and a discharge time of the first peak) from the signal received from measurement equipment.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The IED is connected to the measurement equipment that may be current/ voltage or other electrical parameter sensed from mixed line. Similar concepts are also introduced for an offshore gas production proving the feasibility of utilising IED-based numerical relay for overcurrent detection [15]. These methods detect a travelling wave (peak width of the travelling wave, rise time and a discharge time of the first peak) from the signal received from measurement equipment.…”
Section: Literature Reviewmentioning
confidence: 99%
“…[118] provides a description of some adaptive algorithms that allow the goal to be reached. The use of IEDs not only improves the protection functions along the electricity distribution networks, but also introduces challenges in the field of communications [119], cyber security [120], and in the management of production plants [121].…”
mentioning
confidence: 99%