IntroductionAcquired coagulation disorders are a common cause of neonatal bleeding. The thromboelastograph (TEG) comprehensively assesses haemostatic processes in the body. Unfortunately, the reference range of TEG parameters in the neonatal period has not yet been evaluated, which limits the use of the TEG in neonates. In this study, we aimed to establish the reference range of TEG parameters for the neonatal period.MethodsThis study included 371 full‐term infants (≥37 weeks of gestation), and we divided these infants into three groups according to age as follows: 1, 2‐7 and 8‐28 days. We measured their peripheral blood using TEG, coagulation routine and platelet count tests. We analysed differences among the groups.ResultsThe reference ranges for TEG parameters are presented as medians and reference ranges (2.5th and 97.5th percentiles) as follows: R (clot reaction time, seconds) 4.80 (2.80‐7.17), Angle (fibrin production rate) 69.90 (44.91‐78.89), K (clot kinetics, min) 1.40 (0.80‐4.50), MA (maximum amplitude, mm) 63.50(44.34‐74.66) and LY30 (lysis at 30 minutes, %) 0.10 (0.10‐6.95). There were significant differences in Angle, K, MA and LY30 values between the different neonatal day age groups.ConclusionThis study preliminarily establishes a reference range for TEG parameters during the neonatal period. The age of a newborn had a large influence on TEG parameters. Additionally, we demonstrated a correlation between laboratory tests and TEG parameters for this age period. The reference values provided herein are meaningful for future studies.