2020
DOI: 10.1038/s41440-020-0490-5
|View full text |Cite
|
Sign up to set email alerts
|

Reference values of office central blood pressure, pulse wave velocity, and augmentation index recorded by means of the Mobil‐O‐Graph PWA monitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
26
0
16

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 31 publications
(44 citation statements)
references
References 39 publications
2
26
0
16
Order By: Relevance
“…In a recent analysis, based on triplicate office-based measurements with the Mobilograph device in 5632 participants with cardiovascular risk factors, mean bSBP was 133 (men) and 135 (women) mm Hg, and the corresponding cSBP SBP/DBPcal was 125 (men) and 127 (women) mm Hg. 47 As 24-hour average BP values are generally lower than office blood pressures, our findings regarding cSBP SBP/DBPcal are in good agreement. Similarly, an outcome-based threshold for office cSBP was proposed in a study from Taiwan 48 to be 130 mm Hg.…”
Section: Discussionsupporting
confidence: 76%
“…In a recent analysis, based on triplicate office-based measurements with the Mobilograph device in 5632 participants with cardiovascular risk factors, mean bSBP was 133 (men) and 135 (women) mm Hg, and the corresponding cSBP SBP/DBPcal was 125 (men) and 127 (women) mm Hg. 47 As 24-hour average BP values are generally lower than office blood pressures, our findings regarding cSBP SBP/DBPcal are in good agreement. Similarly, an outcome-based threshold for office cSBP was proposed in a study from Taiwan 48 to be 130 mm Hg.…”
Section: Discussionsupporting
confidence: 76%
“…Várias técnicas têm permitido a medida da PA aórtica (PA central) por meio de algoritmos específicos a partir de medidas de PA obtidas no braço. 233,159 Vários estudos mostraram reduções diferentes na PA central em comparação com a PA braquial com o uso de alguns anti-hipertensivos e, embora a PA central pareça ser um melhor preditor de eventos CV do que a PA braquial, o valor prognóstico incremental da medida da PA central ainda necessita de mais evidências. 160,234 A HA espúria (HA sistólica isolada nos jovens com PA central normal) parece ser a condição mais evidente para o uso da PA central (quando disponível) na prática clínica, o que configura a primeira indicação da medida da PA central.…”
Section: Pressão Aórtica Centralunclassified
“…as causas, segundo a metanálise de Vlachoupoulos et al, com 11 estudos e um total de 5.648 indivíduos, em um seguimento médio de 45 meses 160. Os valores de referência para a pressão central foram estabelecidos pelo grupo europeu em 2014 usando o método tonométrico163 e mais recentemente em um trabalho nacional com equipamentos oscilométricos (Tabela 2.1) 159. A pressão central como preditor de risco cardiovascular é GR: IIa NE: B.…”
unclassified
“…4. Our reference for PWV normal value was 6.9 ± 1.8 and 23 ± 10.9 for AIx [13].…”
Section: Pwv and Augmentation Indexmentioning
confidence: 80%