2010
DOI: 10.1002/nbm.1462
|View full text |Cite
|
Sign up to set email alerts
|

Reliability and precision of pseudo‐continuous arterial spin labeling perfusion MRI on 3.0 T and comparison with 15O‐water PET in elderly subjects at risk for Alzheimer's disease

Abstract: Arterial spin labeling (ASL) offers MRI measurement of cerebral blood flow (CBF) in vivo, and may offer clinical diagnostic utility in populations such as those with early Alzheimer's disease (AD). In the current study, we investigated the reliability and precision of a pseudo-continuous ASL (pcASL) sequence that was performed two or three times within one hour on eight young normal control subjects, and 14 elderly subjects including 11 with normal cognition, one with AD and two with Mild Cognitive Impairment … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

17
295
3
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 258 publications
(316 citation statements)
references
References 42 publications
17
295
3
1
Order By: Relevance
“…Baseline resting cerebral blood flow (CBF) was estimated using a 3D fast spin echo spiral sequence with pseudocontinuous arterial spin labeling (pcASL; Dai et al, 2008;Xu et al, 2010;Okonkwo et al, 2014) and background suppression for quantitative perfusion measurements (TR ϭ 4653 ms, TE ϭ 10.5 ms, postlabeling delay ϭ 1525 ms, labeling duration ϭ 1450 ms, 8 interleaved spiral arms with 512 samples at 62.5 kHz bandwidth and 38 4-mm-thick slices, number of excitations ϭ 3, scan duration ϭ 4.5 min).…”
Section: Methodsmentioning
confidence: 99%
“…Baseline resting cerebral blood flow (CBF) was estimated using a 3D fast spin echo spiral sequence with pseudocontinuous arterial spin labeling (pcASL; Dai et al, 2008;Xu et al, 2010;Okonkwo et al, 2014) and background suppression for quantitative perfusion measurements (TR ϭ 4653 ms, TE ϭ 10.5 ms, postlabeling delay ϭ 1525 ms, labeling duration ϭ 1450 ms, 8 interleaved spiral arms with 512 samples at 62.5 kHz bandwidth and 38 4-mm-thick slices, number of excitations ϭ 3, scan duration ϭ 4.5 min).…”
Section: Methodsmentioning
confidence: 99%
“…In the present study, steady-state CBV measurements from pre-and post-CA T1 measurements (for the Bookend approach) as well as from the VASO method were used to calibrate CBF from DSC-MRI in a test-retest study in 20 healthy subjects, and the results were compared to CBF from pseudo-continuous arterial spin labeling (pCASL). Absolute CBF values from pCASL have previously shown reasonable agreement with reference methods such as PET [11,12], and a comparison between pCASL and calibrated DSC-MRI is thus of relevance. The VASO-and Bookend-calibrated CBF estimates were also mutually compared and the repeatability of the measurements was investigated.…”
Section: Introductionmentioning
confidence: 73%
“…Most studies comparing ASL and other brain perfusion methods have set ROIs manually on the CBF map, 12,[16][17][18] but the manual setting of ROIs introduces inter-rater variability, which is avoided using 3DSRT because the software automatically draws the segmented ROI after registration to an anatomically standardized brain image. In our study, use of 3DSRT allowed detailed comparison in each region of the brain.…”
Section: Discussionmentioning
confidence: 99%
“…Good agreements have already been found between CBF obtained by pCASL at 3.0 tesla and other modalities, such as positron emission tomography (PET) and dynamic susceptibility contrast (DSC) MR imaging. 12,13 Iodine-123-N-isopropyl-p-iodoamphetamine (IMP) single photon emission computed tomography (SPECT) using autoradiography (ARG) is an established standard method to assess CBF, with substantial evidence accumulated in nuclear medicine. It is known that CBF values show good correlation between IMP SPECT and PET using H 2 15 O or C 15 O 2 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation