2016
DOI: 10.1080/09553002.2016.1222092
|View full text |Cite
|
Sign up to set email alerts
|

RENEB biodosimetry intercomparison analyzing translocations by FISH

Abstract: The results obtained indicate that, despite the problems identified in few partners, which can be corrected, the RENEB consortium is able to carry out retrospective biodosimetry analyzing the frequency of translocations by FISH.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
19
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 27 publications
2
19
0
Order By: Relevance
“…Key to the Bayesian concept is the application of the inversion theorem in its continious version, i.e. : (4) where D denotes the unknown parameter (absorbed dose) and X obs the observation (the dicentric yield within the sample, y, and the calibration data). Thus, the posterior dose distribution (or calibrative dose density), P(D|X obs ), scales with the product of the likelihood (or predictive density) P(X obs |D) and the prior P(D):…”
Section: Probabilistic Approach: Bayesian Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Key to the Bayesian concept is the application of the inversion theorem in its continious version, i.e. : (4) where D denotes the unknown parameter (absorbed dose) and X obs the observation (the dicentric yield within the sample, y, and the calibration data). Thus, the posterior dose distribution (or calibrative dose density), P(D|X obs ), scales with the product of the likelihood (or predictive density) P(X obs |D) and the prior P(D):…”
Section: Probabilistic Approach: Bayesian Methodsmentioning
confidence: 99%
“…DCA, PCC and CBMN show stability of responses for several months, as induction of these aberrations means the cells cannot reproduce and thus the cells die and these aberrations are gradually removed from the population of circulating lymphocytes, Therefore, the relative specificity to ionising radiation drives the accuracy of these methods. In contrast, γ-H2AX and FISH are not radiation specific, however, the individual background levels are becoming more well understood 4,6,32 . The vast majority of γ-H2AX aberrations disappear within approximately 24 hours and thus this is very much a short term assay, however, translocations detected by FISH are stable over many years.…”
Section: Biodosimetrymentioning
confidence: 99%
See 1 more Smart Citation
“…Efforts could be made to reduce uncertainties, but one might wonder if this is really necessary, regarding the contribution of the reference Table 2. Summary of reference doses used for the second inter-laboratory comparison (ILC) as in Barrios et al (2016) dosimetry to the total uncertainties budget in biological dosimetry. The target in terms of accuracy for such ILC programs remains to be discussed for biological applications and a reasonable target for accuracy has to be defined.…”
Section: Discussionmentioning
confidence: 99%
“…The first five assays rely on analysing peripheral blood lymphocytes and the last two assays on analysing components of personal electronic devices (PED), such as smartphones. The assays are described elsewhere Barquinero et al 2016;Depuydt et al 2016;Moquet et al 2016;Terzoudi et al 2016;Trompier et al 2016). An example of a dosimetric data set for 10 patients and the correct triage classification is shown in Table 1.…”
Section: Methodsmentioning
confidence: 99%