2005
DOI: 10.1016/j.ijrefrig.2005.07.006
|View full text |Cite
|
Sign up to set email alerts
|

Residential CO2 heat pump system for combined space heating and hot water heating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
75
0
5

Year Published

2009
2009
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 149 publications
(82 citation statements)
references
References 13 publications
2
75
0
5
Order By: Relevance
“…Fewer theoretical and experimental studies have been conducted for the performance analysis on CO2 heat pump water heating systems. Some studies have been conducted under steady states: Cecchinato et al have investigated the performance of a water heater by a simulation model in consideration of the influence of inlet water temperature by assuming perfect stratification and mixing in a storage tank [23]; Stene has conducted theoretical and experimental studies on the performance of a heat pump for combined space and water heating in consideration of the influence of inlet water temperature due to heat conduction in a storage tank [24];…”
Section: Introductionmentioning
confidence: 99%
“…Fewer theoretical and experimental studies have been conducted for the performance analysis on CO2 heat pump water heating systems. Some studies have been conducted under steady states: Cecchinato et al have investigated the performance of a water heater by a simulation model in consideration of the influence of inlet water temperature by assuming perfect stratification and mixing in a storage tank [23]; Stene has conducted theoretical and experimental studies on the performance of a heat pump for combined space and water heating in consideration of the influence of inlet water temperature due to heat conduction in a storage tank [24];…”
Section: Introductionmentioning
confidence: 99%
“…Some studies have been conducted for the performance analysis on water heating systems (Cecchinato et al, 2005;Stene, 2005;Minetto, 2011). However, few studies have been conducted in consideration of daily changes in the aforementioned conditions.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, the system performance is affected by the operational history on past several days, and changes complexly with days. Therefore, in order to attain the maximum system performance, it is necessary to estimate the daily changes in system performance values accurately in relation to those in the ambient conditions, hot water demand, and operating conditions, and determine the operating conditions optimally based on them.Some studies have been conducted for the performance analysis on water heating systems (Cecchinato et al, 2005;Stene, 2005;Minetto, 2011). However, few studies have been conducted in consideration of daily changes in the aforementioned conditions.…”
mentioning
confidence: 99%
“…Hence the annual heating demand for SHW has a higher share of the total heating demand in new houses. The SHW ratio 1 usually ranges from 20 to 45% in new and low-energy houses (Stene, 2005). Therefore, SHW production is an interesting case study in 2 Chapter 1 Introduction order to make the process more efficient and have a great impact on the total energy consumption.…”
Section: Motivationmentioning
confidence: 99%
“…Works like (Cecchinato et al, 2005;Nekså et al, 1998;Nekså, 2002;Rieberer et al, 1997) has shown high efficiency of these cycles at water temperature lifts even higher than 50K. Stene (2004) discussed the existence of the gas cooler pinch point and the effect of the rejection pressure control for CO2 heat pump water heaters. Figure 1.3 illustrates the result of increasing the rejection pressure from 85 bar to 110 bar for a CO2 heat pump water heater, where water is heated up from 5ᵒC to 70ᵒC.…”
Section: The Transcritical Co2 Cyclementioning
confidence: 99%