Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference
DOI: 10.1109/nssmic.1991.259189
|View full text |Cite
|
Sign up to set email alerts
|

Resolution and sensitivity improvement in positron emission tomography by the first interaction point determination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…Because the inter-detector scatter degrades crystal identification and DOI accuracy, it can be expected that the inter-detector scatter leads the spatial resolution loss of the detector module. To eliminate the artifact due to the detector scatter, algorithms to find the first interaction position in multiple interactions (detector scatter) were investigated [72,73]. However, the study based on Monte Carlo simulation indicated that detector scatter may have a small effect (6%~8%) on the image resolution (FWHM) of a reconstructed point source for the DOI capable detector systems [74][75][76].…”
Section: Discussionmentioning
confidence: 99%
“…Because the inter-detector scatter degrades crystal identification and DOI accuracy, it can be expected that the inter-detector scatter leads the spatial resolution loss of the detector module. To eliminate the artifact due to the detector scatter, algorithms to find the first interaction position in multiple interactions (detector scatter) were investigated [72,73]. However, the study based on Monte Carlo simulation indicated that detector scatter may have a small effect (6%~8%) on the image resolution (FWHM) of a reconstructed point source for the DOI capable detector systems [74][75][76].…”
Section: Discussionmentioning
confidence: 99%
“…Through simulations, previous work explored various algorithms to determine the position of initial interaction to eliminate effect of inter-crystal Compton scatter [1], as well as the impact of Compton scatter event recovery on system resolution and sensitivity improvements of a non-ToF-PET scanner [2].…”
Section: Introductionmentioning
confidence: 99%
“…If ICS happens, position decoding using the center of gravity method will provide incorrect gamma ray interaction positions, which affects both the spatial (transversal-axial direction) and DOI (radial direction) resolution. This blur in detector resolution causes degradation of the reconstructed image [11,12]. Rejection of ICS events has been used to improve spatial resolution [13], however, this method also reduces system sensitivity.…”
Section: Introductionmentioning
confidence: 99%