Resolution of 13 Polycyclic Aromatic Hydrocarbons by Constant-wavelength Synchronous Spectrofluorometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2009
2009
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 31 publications
0
2
0
1
Order By: Relevance
“…The bile from control and PAHs1 animals had smaller increases in compounds corresponding to the 250e390 nm range of the spectrum when compared to the bile from PAHs2 animals. These compounds include benz(a)pyrene and benz(a)anthracene, which have lower acute toxicity and higher mutagenic and carcinogenic potential (Lage-Yusty et al, 2005;Hylland, 2006). It is possible that the low acute toxicity of these PAHs explains the normal behavior of groupers during the experiment.…”
Section: Discussionmentioning
confidence: 99%
“…The bile from control and PAHs1 animals had smaller increases in compounds corresponding to the 250e390 nm range of the spectrum when compared to the bile from PAHs2 animals. These compounds include benz(a)pyrene and benz(a)anthracene, which have lower acute toxicity and higher mutagenic and carcinogenic potential (Lage-Yusty et al, 2005;Hylland, 2006). It is possible that the low acute toxicity of these PAHs explains the normal behavior of groupers during the experiment.…”
Section: Discussionmentioning
confidence: 99%
“…In conventional fluorescence spectroscopy, excitation and emission spectra are used for the analysis. In case of overlapping spectra, the synchronous fluorescence spectroscopy (SFS) [2][3][4][5][6][7][8][9] may help with its sharper and more separated spectral bands. Among the several variations of SFS and derivative SFS we will focus now on the matrix isopotential synchronous fluorimetry (MISF) [10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…Nessa técnica a velocidade de escaneamento é mantida constante em ambos os monocromadores e, portanto, um intervalo constante no comprimento de onda, ∆λ, é mantido entre λem e λex. Devido as características do espectro, a fluorescência sincronizada vem sendo utilizada como uma metodologia simples e efetiva para a obtenção de dados de vários compostos em uma única medida, permitindo a análise de amostras biológicas (EL-ENANY et at, 2009;PULGARÍN et al, 2012;ELMANSI et al, 2016;NI et al, 2008;LI et al, 2009), ambientais (HUA et al, 2006;LIU et al, 2006), petroquímicas (XIA et al, 2006;RYDER et al, 2004;LAGE-YUSTY et al, 2005;HE et at, 2005) e alimentos (PÍŠ et al, 2011;PATRA et al, 2011;PULGARÍN et al, 2014;SIKORSKA et al, 2006;ZHOU et al, 2011), sem a necessidade de uma etapa prévia de pré-separação. (Rocha et al, 2015).…”
Section: Fluorescência Sincronizadaunclassified