2000
DOI: 10.1016/s0360-3016(00)00524-1
|View full text |Cite
|
Sign up to set email alerts
|

Respiratory gated irradiation system for heavy-ion radiotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
308
4

Year Published

2006
2006
2023
2023

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 432 publications
(312 citation statements)
references
References 11 publications
0
308
4
Order By: Relevance
“…During treatment, patient‐machine alignment was achieved via the overlapping of the onboard image taken in a true lateral position with a kilovoltage X‐ray with the reconstructed 2‐dimensional image taken at planning CT; deviations in the skeletal anatomy, diaphragm, and inserted fiducial markers were minimized between the 2 images. Respiratory gating at the end of the expiratory phase was used for CT planning, positional verification on the treatment board, and irradiation 21. These treatment methods were the same for the 2 protocols.…”
Section: Methodsmentioning
confidence: 99%
“…During treatment, patient‐machine alignment was achieved via the overlapping of the onboard image taken in a true lateral position with a kilovoltage X‐ray with the reconstructed 2‐dimensional image taken at planning CT; deviations in the skeletal anatomy, diaphragm, and inserted fiducial markers were minimized between the 2 images. Respiratory gating at the end of the expiratory phase was used for CT planning, positional verification on the treatment board, and irradiation 21. These treatment methods were the same for the 2 protocols.…”
Section: Methodsmentioning
confidence: 99%
“…In the gating technique, the patient is treated at a particular phase of free breathing, generally by placing an external marker on the patient's chest and synchronizing beam delivery with the motion of the marker. ( 12 14 ) For this group of patients, the treatment plan should be based on a breathing‐adapted imaging technique. Four‐dimensional computed tomography (4D‐CT) is such a technique ( 15 – 19 ) and the focus of the present work.…”
Section: Introductionmentioning
confidence: 99%
“…Gating [10][11][12] and tracking techniques [13,14] using external surrogates have also been reported in particle therapy. However, internal organ motions and the external surrogate signals of abdominal motion are not necessarily correlated during treatment [15].…”
Section: Introductionmentioning
confidence: 99%