Response surface optimization of chemical coagulation for solid–liquid separation of dairy manure slurry through Box–Behnken design with desirability function
“…It has been reported that CPAM could effectively improve wastewater coagulation via adsorption and aggregation of micro-flocs. 20 The landfill leachate concentrate was stirred rapidly at 250 r min −1 for 2 min and then stirred slowly at 60 r min −1 for 10 min before natural settling for approximately 30 min at room temperature (25 ± 2 °C). All coagulation tests were performed in triplicate.…”
This study investigated the impacts of different coagulants on the performance of membrane distillation (MD) for landfill leachate concentrate treatment.
“…It has been reported that CPAM could effectively improve wastewater coagulation via adsorption and aggregation of micro-flocs. 20 The landfill leachate concentrate was stirred rapidly at 250 r min −1 for 2 min and then stirred slowly at 60 r min −1 for 10 min before natural settling for approximately 30 min at room temperature (25 ± 2 °C). All coagulation tests were performed in triplicate.…”
This study investigated the impacts of different coagulants on the performance of membrane distillation (MD) for landfill leachate concentrate treatment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.