2003
DOI: 10.1063/1.1615093
|View full text |Cite
|
Sign up to set email alerts
|

Results about imaging with silicon strips for Angiography and Mammography

Abstract: We present results obtained with a single photon counting system consisting of 384 silicon microstrips of 100 micron pitch equipped with 6 RX64 ASICs. The ASIC includes a charge preamplifier, a shaper, a discriminator and a 20-bit counter for each of its 64 channels. The energy resolution of the system has been measured in the range from 8 keV to 32 keV using fluorescence Xray lines from several targets, using either an Am-241 source or an X-ray tube. Then, the efficiency of the system has been determined usin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2003
2003
2005
2005

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…Images of the phantom have been acquired at the two energies of the dichromatic beam using a detection system capable of single photon counting. The detector is a prototype (Baldazzi et al 2003a(Baldazzi et al , 2003b(Baldazzi et al , 2003c) based on an array of 384 silicon microstrips equipped with read-out electronics of 6 RX64 ASICs: each strip is 1 cm long, has a pixel pitch of 100 µm and a depth of 300 µm. We used the detection system in edge-on configuration, i.e putting the microstrips parallel to the incoming beam.…”
Section: Detection Systemmentioning
confidence: 99%
“…Images of the phantom have been acquired at the two energies of the dichromatic beam using a detection system capable of single photon counting. The detector is a prototype (Baldazzi et al 2003a(Baldazzi et al , 2003b(Baldazzi et al , 2003c) based on an array of 384 silicon microstrips equipped with read-out electronics of 6 RX64 ASICs: each strip is 1 cm long, has a pixel pitch of 100 µm and a depth of 300 µm. We used the detection system in edge-on configuration, i.e putting the microstrips parallel to the incoming beam.…”
Section: Detection Systemmentioning
confidence: 99%
“…Mammographic imaging experiments were performed in 2002 and 2003 at the quasi-monochromatic beam facility located at University of Ferrara; preliminary results were previously reported. 19,20 The dual-energy analysis procedure was applied to the data obtained from the experiment as well as to those obtained from a Monte Carlo simulation of the experimental setup. For the simulation the particle transport code MCNP-4C was used.…”
Section: Introductionmentioning