2014
DOI: 10.1167/iovs.13-13255
|View full text |Cite
|
Sign up to set email alerts
|

Retinal Oximetry With a Scanning Laser Ophthalmoscope

Abstract: Technically, it is possible to derive information on retinal oxygen saturation from an SLO with a 2-wavelength oximetry algorithm. The system produced both sensitive and repeatable results. The remaining challenges include decreasing variability between vessels of the same eye and variability between individuals. Given the advantages that SLO imaging has over conventional fundus camera optics in retinal oximetry, further development of SLO oximetry may provide the optimal approach to retinal oximetry.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
33
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(34 citation statements)
references
References 20 publications
1
33
0
Order By: Relevance
“…As the optical absorption coefficient of whole blood is the linear combination of these two forms of hemoglobin, multi-wavelength spectroscopy can be used to retrieve relative HbO 2 -HbR concentration ratio and thus sO 2 . Fundus photography [4][5][6][7], scanning laser ophthalmoscopy [19], and hyperspectral imaging [20,21] have all been investigated to measure retinal circulation sO 2 in humans. These approaches rely on the backscattered photons from blood vessels and share similar imaging principle.…”
Section: Introductionmentioning
confidence: 99%
“…As the optical absorption coefficient of whole blood is the linear combination of these two forms of hemoglobin, multi-wavelength spectroscopy can be used to retrieve relative HbO 2 -HbR concentration ratio and thus sO 2 . Fundus photography [4][5][6][7], scanning laser ophthalmoscopy [19], and hyperspectral imaging [20,21] have all been investigated to measure retinal circulation sO 2 in humans. These approaches rely on the backscattered photons from blood vessels and share similar imaging principle.…”
Section: Introductionmentioning
confidence: 99%
“…Adding new wavelengths will make the system achieve multi-spectral imaging. Multi-spectral retinal imaging has gained interest in recent years [30,31] as it helps gathering quantitative information on retinal health.…”
Section: Discussionmentioning
confidence: 99%
“…After model test and uncertainty analysis, we used the testing data from Ref. [12] and applied the FNN and CNN models for retinal imaging oximetry in comparison to LSF (Fig. 6), at three different ventilation conditions.…”