2016
DOI: 10.1007/s00521-016-2578-z
|View full text |Cite|
|
Sign up to set email alerts
|

RETRACTED ARTICLE: A new approach to eliminating EOG artifacts from the sleep EEG signals for the automatic sleep stage classification

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 30 publications
0
7
0
1
Order By: Relevance
“…Sleep stage detection and recognition is an important basis for measuring and evaluating sleep quality. Sleep stage detection and recognition is usually conducted with polysomnography (PSG), including electroencephalogram (EEG), electrooculogram (EOG), electromyogram (EMG), electrocardiogram (ECG), chest and abdomen movements, pulse oxygenation, and snoring [ 13 , 14 ]. These technologies involve the use of a considerable number electrodes, which is very inconvenient for the measurement and treatment of sleep disorders and may bring physical and psychological interference to patients, and even affect the quality of sleep [ 15 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Sleep stage detection and recognition is an important basis for measuring and evaluating sleep quality. Sleep stage detection and recognition is usually conducted with polysomnography (PSG), including electroencephalogram (EEG), electrooculogram (EOG), electromyogram (EMG), electrocardiogram (ECG), chest and abdomen movements, pulse oxygenation, and snoring [ 13 , 14 ]. These technologies involve the use of a considerable number electrodes, which is very inconvenient for the measurement and treatment of sleep disorders and may bring physical and psychological interference to patients, and even affect the quality of sleep [ 15 ].…”
Section: Introductionmentioning
confidence: 99%
“…Invasive EEG causes irreversible damage to the brain, whereas non-invasive EEG (scalp EEG) has very low spatial resolution [ 5 ]. The use of EMG and EOG in detecting the sleep has undergone considerable progress but these methods rely on too many physiological traits and physiological response in the time dimension tends to be delayed by 5–6 s, which limits the time dynamics of the brain’s stimulus response; the low temporal and spatial resolution may also ignore some important information in the signal [ 13 , 14 ].…”
Section: Introductionmentioning
confidence: 99%
“…This method estimates alertness level based on eye movement [78]. Specifically, it measures the electrical signal representing the potential difference between the cornea and retina of a subject's eye [79], [80]. In this method, an electrode is placed near the end of each eye and another is placed at top of the eye.…”
Section: F Electro-oculogram (Eog)mentioning
confidence: 99%
“…Pada pengolahan sinyal EEG, sinyal EOG menjadi noise yang cukup signifikan dimana amplitude sinyal EOG yang lebih tinggi dibandingkan dengan sinyal EEG [7]. Untuk itu diperlukan metode khusus untuk menghilangkan sinyal EOG pada rekaman sinyal EEG [8]. Sementara itu pada pengolahan sinyal EMG, pada kasus tertentu tidak semua pasien bisa menggunakan sinyal EMG utamanya pada pasien kelumpuhan total [9].…”
Section: B Pengolahan Sinyal Eogunclassified