2011
DOI: 10.1007/s12161-011-9219-z
|View full text |Cite
|
Sign up to set email alerts
|

Reversed Electrode Polarity Stacking Sample Preconcentration Combined with Micellar Electrokinetic Chromatography for the Analysis of Carbamate Insecticide Residues in Fruit Juices

Abstract: Reversed electrode polarity stacking mode (REPSM) coupled to micellar electrokinetic chromatography (MEKC) was employed for the simultaneous determination of carbamate insecticide residues in fruit juice samples. A mixture of the studied insecticides (i.e., methomyl, propoxur, carbofuran, carbaryl, isoprocarb, and promecarb) in 10 mmol L −1 phosphate buffer (pH 7.0) was introduced into the capillary tube by hydrodynamic injection at 0.5 psi for 30 s followed by removal of the sample matrix at −15 kV for 0.5 mi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 34 publications
0
9
0
Order By: Relevance
“…The LOD was reduced from 1.7 mg/L to 2.8 μg/L for melamine by the optimum cation‐selective injection step, and from 0.23–1.2 mg/L to 2.4–5.0 μg/L for the other three analytes by the optimum REPSM step. REPSM coupled to micellar MEKC was employed for the simultaneous determination of carbamate insecticide residues in fruit juice samples . The analytes were separated using a BGE containing 10 mM borate and 60 mM SDS at pH 9.5.…”
Section: Micellar Methodsmentioning
confidence: 99%
“…The LOD was reduced from 1.7 mg/L to 2.8 μg/L for melamine by the optimum cation‐selective injection step, and from 0.23–1.2 mg/L to 2.4–5.0 μg/L for the other three analytes by the optimum REPSM step. REPSM coupled to micellar MEKC was employed for the simultaneous determination of carbamate insecticide residues in fruit juice samples . The analytes were separated using a BGE containing 10 mM borate and 60 mM SDS at pH 9.5.…”
Section: Micellar Methodsmentioning
confidence: 99%
“…The obtained enrichment factors ranged from 479 to 610, and the LODs ranged from 0.02 to 0.04 ng/g. Santalad et al [ 94 ] proposed a reversed-electrode polarity mode coupled MEKC for the analysis of carbamate insecticides residues in fruit juices. This method gave enrichment factors of about 4 to 13 and LODs of 0.01 to 0.10 mg/L.…”
Section: On-line Preconcentration Of Pesticides By Capillary Electmentioning
confidence: 99%
“…Some analytical methods have been developed for carbamates including IPC, such as GC , ELISA , MEKC , biosensors , HPLC , and HPLC–MS . But the thermal instability of IPC does not permit the direct determination by GC unless it is derived into thermally stable derivatives.…”
Section: Introductionmentioning