1997
DOI: 10.1016/s0021-9673(97)00427-5
|View full text |Cite
|
Sign up to set email alerts
|

Reversed-phase C18 high-performance liquid chromatography of gibberellins GA3 and GA1

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 11 publications
0
14
0
Order By: Relevance
“…The ␤-tubulin gene from F. fujikuroi, amplified with primers 5Ј-CCGGTGCTGGAAACAACTG-3Ј and 5Ј-CGAGGACCTGGTCGACAAG T-3Ј, (16) Chemical determinations. For gibberellic acid (GA 3 ) determinations, 1-ml samples were acidified to pH 2.5 with 10 M HCl, cleaned by filtration through 0.22-m-pore Millipore filters, and run in an HPLC device (Agilent Technologies, Santa Clara, CA) with 30% methanol and 10 mM H 3 PO 4 (pH 3) (14). Concentrations were obtained from the peaks at 206 nm of commercial GA 3 (Sigma, Saint Louis, MO) used as a standard.…”
Section: Methodsmentioning
confidence: 99%
“…The ␤-tubulin gene from F. fujikuroi, amplified with primers 5Ј-CCGGTGCTGGAAACAACTG-3Ј and 5Ј-CGAGGACCTGGTCGACAAG T-3Ј, (16) Chemical determinations. For gibberellic acid (GA 3 ) determinations, 1-ml samples were acidified to pH 2.5 with 10 M HCl, cleaned by filtration through 0.22-m-pore Millipore filters, and run in an HPLC device (Agilent Technologies, Santa Clara, CA) with 30% methanol and 10 mM H 3 PO 4 (pH 3) (14). Concentrations were obtained from the peaks at 206 nm of commercial GA 3 (Sigma, Saint Louis, MO) used as a standard.…”
Section: Methodsmentioning
confidence: 99%
“…Table 4 indicates the average of 4 results obtained by SIA with the tubular detector (TE), the analysis of the same samples through direct potentiometry in batch conditions with the previously described electrode 7 and with an independent method based on the HPLC technique. 2 As can be observed the proposed procedure gave results with lower relative errors (< 0.5%) relatively to those provided by conventional units (< 3.3%) when both are compared with the HPLC method. The improvement of the analytical results is more significant when the complexity of sample increases, such as the case of Berelex formulation.…”
Section: Analytical Applicationsmentioning
confidence: 66%
“…In the real sample analysis by the HPLC method proposed by Martinez et al, 2 the mobile phase was made up of a degasified mixture of 300.0 mL of methanol and 700.0 mL of a 10 -2 mol L -1 phosphoric acid solution whose pH was previously adjusted to 3.0 with 0.1 mol L -1 KOH. This eluent was also used for the preparation of a 1 mg mL -1 gibberellic acid standard solution and as solvent of the remaining less-concentrated solutions.…”
Section: Introductionmentioning
confidence: 99%
“…6 Many of them respond to environmental stimuli such as photoperiod, temperature, water and nutrition supply. 7 Taking gibberellic acid as an example, it promotes seed germination, stem elongation, flowering and cone production, and retards leaf and fruit senescence. It also induces de novo synthesis of numerous enzymes.…”
Section: Introductionmentioning
confidence: 99%