2001
DOI: 10.1016/s0021-9673(00)01073-6
|View full text |Cite
|
Sign up to set email alerts
|

Reversed-phase high-performance liquid chromatography versus spectrophotometric assay for thimerosal in Cuban recombinant hepatitis B vaccine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2015
2015
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 16 publications
0
9
0
Order By: Relevance
“…On the other hand, literature data clearly indicate that cation RHg + reacts with DT to form chelates with 1:1 ratio [51,54]. TM, as the compound with polarized S-Hg bond, C 2 H 5 -Hg δ+ -δ− S-C 6 H 4 -COO − Na + , undergoes cleavage in solution induced by, e.g., light or temperature [7,10,[36][37][38][39]. Consequently, thiosalicylate anion is labile [8] and can be exchanged by stronger nucleophile, e.g., DT ligand.…”
Section: The Problem Of Tm and Al Simultaneous Determinationmentioning
confidence: 99%
See 3 more Smart Citations
“…On the other hand, literature data clearly indicate that cation RHg + reacts with DT to form chelates with 1:1 ratio [51,54]. TM, as the compound with polarized S-Hg bond, C 2 H 5 -Hg δ+ -δ− S-C 6 H 4 -COO − Na + , undergoes cleavage in solution induced by, e.g., light or temperature [7,10,[36][37][38][39]. Consequently, thiosalicylate anion is labile [8] and can be exchanged by stronger nucleophile, e.g., DT ligand.…”
Section: The Problem Of Tm and Al Simultaneous Determinationmentioning
confidence: 99%
“…Determination of thimerosal in pharmaceuticals is carried out in two ways: as total Hg [26][27][28][29][30][31][32][33][34] or directly as thimerosal [35][36][37][38][39][40][41][42][43][44]. The total Hg determination methods require mineralization and atomization of sample to form mercury vapor.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The detection of THM at trace level in environmental samples is of crucial importance. In the past, various analytical techniques including HPLC with electrochemical detection, enzymatic amperometry, colorimetry, atomic absorption spectrometry, and atomic fluorescence spectrometry have been developed to detect THM and derivatives . As an alternative, mass spectrometry detectors are preferable in terms of sensitivity, accuracy, generated waste and others requirements of routine analysis, however, the equipment and running costs are prohibitive to many laboratories .…”
Section: Introductionmentioning