2018
DOI: 10.1016/j.wneu.2018.08.157
|View full text |Cite
|
Sign up to set email alerts
|

Robot-Assisted Versus Fluoroscopy-Assisted Cortical Bone Trajectory Screw Instrumentation in Lumbar Spinal Surgery: A Matched-Cohort Comparison

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

8
82
0
2

Year Published

2019
2019
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 100 publications
(92 citation statements)
references
References 23 publications
8
82
0
2
Order By: Relevance
“…There are several orthopaedic surgical robots that have been reported to be suitable for pedicle screw fixation, including the TiRobot, ROSA, SpineAssist, and Renaissance. Some studies have compared the robot‐assisted (RA) technique with the conventional technique, mainly focused on the intra‐pedicle accuracy of pedicle screws and radiation exposure. While some studies have compared the presence of FJV, to the best of our knowledge, no study has mentioned a specific FJV degree of these two techniques.…”
Section: Introductionmentioning
confidence: 99%
“…There are several orthopaedic surgical robots that have been reported to be suitable for pedicle screw fixation, including the TiRobot, ROSA, SpineAssist, and Renaissance. Some studies have compared the robot‐assisted (RA) technique with the conventional technique, mainly focused on the intra‐pedicle accuracy of pedicle screws and radiation exposure. While some studies have compared the presence of FJV, to the best of our knowledge, no study has mentioned a specific FJV degree of these two techniques.…”
Section: Introductionmentioning
confidence: 99%
“…The TianJi Robot system with a robotic arm is not a "bone-mounted" robot and preoperative CT scans are not required because intraoperative images obtained by C-arm scanning are used for registration. A high level of accuracy for screw insertion and a reliable, safe process were demonstrated through the clinical use of the TianJi Robot system 18,19 . During our current study, we used the TianJi Robot system to assist in the transfacet screw insertion supplementing OLIF procedure.…”
Section: Introductionmentioning
confidence: 99%
“…Other Fluoroscopy time [14][15][16][20][21][22][23][25][26][27]30,32 Egger's test 0.00 0.999 False Radiation dose [13][14][15][16]19,20,22,25,26,30,32 Egger's test À 0.59 0.572 False Operative time [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26]30,32 Egger's test 0.32 0.753 False Length of hospital stay 5,[12][13][14][15][16][20][21][22]32 Egger's test À 2.20 0.052 False Complication rate…”
Section: Limitationsmentioning
confidence: 99%