Robust electrical impedance tomography for biological application: A mini review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 104 publications
0
3
0
Order By: Relevance
“…In the potential field of EIT, current is distributed dominantly near the excitation electrodes and thus the resulting potential decreases as the measurement electrode is located further away from the excitation electrodes (Wu et al 2021), as shown in figure 9. Because the voltmeter has the same noise power, SNR of the measured impedance at the far-end electrode becomes smaller compared to that at the near-end electrode (Li et al 2023). In terms of the distance between electrodes of measurement and electrodes, there are more electrodes far from the excitation electrodes in adjacent injection than those in opposite injection; therefore, the impedance obtained from these measurement channels was much smaller than that with opposite injection (figure 9).…”
Section: Assessment Of Eit Signal Qualitymentioning
confidence: 99%
“…In the potential field of EIT, current is distributed dominantly near the excitation electrodes and thus the resulting potential decreases as the measurement electrode is located further away from the excitation electrodes (Wu et al 2021), as shown in figure 9. Because the voltmeter has the same noise power, SNR of the measured impedance at the far-end electrode becomes smaller compared to that at the near-end electrode (Li et al 2023). In terms of the distance between electrodes of measurement and electrodes, there are more electrodes far from the excitation electrodes in adjacent injection than those in opposite injection; therefore, the impedance obtained from these measurement channels was much smaller than that with opposite injection (figure 9).…”
Section: Assessment Of Eit Signal Qualitymentioning
confidence: 99%
“…Both disciplines struggle with huge datasets and complex data processing requirements. For the correct and effective reconstruction of medical pictures, computational geophysical techniques like tomography and inversion techniques are being used [ 26 ]. Simultaneously, advances in the interpretation of geophysical data are being driven by the complex algorithms created in the health sciences, such as ML for medical picture analysis [ 27 ].…”
Section: Introductionmentioning
confidence: 99%
“…Electromagnetic fields find various applications in medicine, including tissue ablation using thermal energy deposition at microwave and radiofrequency frequencies 1 , medical imaging with electrical impedance tomography 2 , nerve and muscle stimulation 3 , bone regeneration 3 , and more. Each of these applications employs specific electromagnetic field frequencies, intensities, and durations tailored to their purposes.…”
Section: Introductionmentioning
confidence: 99%