Robust high spatio-temporal line-scanning fMRI in humans at 7T using multi-echo readouts, denoising and prospective motion correction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
29
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(30 citation statements)
references
References 61 publications
1
29
0
Order By: Relevance
“…However, since GELINE and SELINE data were acquired in the same session and the same subjects, we would expect any motion problems to be similar in both acquisitions and hence conclude that motion is not the main cause for the observed differences in SELINE and GELINE. Moreover, the current setup does not allow for motion correction, but a prospective motion correction module could be introduced in future implementations [34].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, since GELINE and SELINE data were acquired in the same session and the same subjects, we would expect any motion problems to be similar in both acquisitions and hence conclude that motion is not the main cause for the observed differences in SELINE and GELINE. Moreover, the current setup does not allow for motion correction, but a prospective motion correction module could be introduced in future implementations [34].…”
Section: Discussionmentioning
confidence: 99%
“…Prospective motion correction would allow scanning people for a very long time. However, the current implementation of SELINE does not include prospective motion correction [34]. For this reason, at this stage we cannot provide the reader with an estimate of how long one would need to scan to see activation in SELINE data.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…With this sequence, 94.3 ± 1.3% of undesired signal outside the region of interest is suppressed (Raimondo, Knapen, et al, 2021, Raimondo, Priovoulos, et al, 2023. A gap of 4 mm between the two OVS bands was used, resulting in a nominal resolution for the line of 4 Â 2.5 Â 0.25 mm 3 ; thus, 0.25 mm in the laminar direction.…”
Section: Session 2-line-scanningmentioning
confidence: 99%
“…saturation slabs, there are contaminating signals coming from outside the region-of-interest (Raimondo, Knapen, et al, 2021;Raimondo, Priovoulos, et al, 2023). Because the full registration cascade from target vertex to the line through the low-resolution image, partial…”
Section: Anatomical Measures Confirm Accurate Lineplanningmentioning
confidence: 99%