2015
DOI: 10.1016/j.chroma.2015.07.069
|View full text |Cite
|
Sign up to set email alerts
|

Robust naphthyl methacrylate monolithic column for high performance liquid chromatography of a wide range of solutes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…biphenyl ligands, on the surface of the OHM precursor. Through the course of monolithic column development, aromatic acrylate monolithic capillary columns emerged , and more recently, other promising aromatic monolithic stationary phases appeared . This is not surprising since there has been a noticeable rise in the commercial availability of phenyl type reversed‐phase columns for HPLC separations due to their unique retention mechanism.…”
Section: Introductionmentioning
confidence: 99%
“…biphenyl ligands, on the surface of the OHM precursor. Through the course of monolithic column development, aromatic acrylate monolithic capillary columns emerged , and more recently, other promising aromatic monolithic stationary phases appeared . This is not surprising since there has been a noticeable rise in the commercial availability of phenyl type reversed‐phase columns for HPLC separations due to their unique retention mechanism.…”
Section: Introductionmentioning
confidence: 99%
“…The retention behaviors of FA‐6AQ derivatives were first evaluated on the in‐house made napthyl methacrylate monolithic column (NMM column), which was designed recently in our laboratory, and its usefulness has been demonstrated in the separation of both small and large molecules . In general, monolithic columns are supposed to have a characteristic large pore size, which is appropriate for the separation of FAs especially those with long carbon chains.…”
Section: Resultsmentioning
confidence: 99%
“…Chromatographic separations were performed on a 5 μm wide pore C4 functionalized silica particles column (C4 column), 15 cm × 4.6 mm id, from J.T. Baker (Phillipsburg, NJ, USA), a 5 μm Nucleosil CN functionalized silica (CN column), 15 cm × 4.6 mm id, and an in‐house synthesized naphthyl functionalized organic monolithic column (NMM column), 10 cm × 4.6 mm id .…”
Section: Methodsmentioning
confidence: 99%
“…Recently, Jonnada and El Rassi have introduced an organic monolithic column by the in situ copolymerization of 2‐naphthyl methacrylate as the functional monomer and trimethylolpropane trimethacrylate (TRIM) as the cross‐linker in a stainless steel column of 4.6 mm id for RPC . The column showed high mechanical stability and good hydrodynamic characteristics with virtually “zero” compressibility over a long period of daily use with a wide range of mobile phase compositions.…”
Section: Nonpolar Organic Monolithsmentioning
confidence: 99%
“…Gradient elution: 5–60% B in 30 min (A); 10–80% B in 10 min (B); 15–60% B in 1 min (C). Peaks: (1) ribonuclease A, (2) cytochrome C, (3) lysozyme, (4) β‐lactoglobulin A, (5) myoglobin, (6) α‐chymotrypsinogen A. Reproduced with permission from .…”
Section: Nonpolar Organic Monolithsmentioning
confidence: 99%