2010
DOI: 10.1016/j.ajodo.2009.10.027
|View full text |Cite
|
Sign up to set email alerts
|

Root-contact evaluation by panoramic radiography and cone-beam computed tomography of super-high resolution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(16 citation statements)
references
References 20 publications
0
16
0
Order By: Relevance
“…5,13,18 Despite the changes in teeth position due to orthodontic treatment, 8,18 CBCT scans produce a high level of reproducibility, which reasserts its use in orthodontics. 5,17,18 In order to evaluate root length, an in vitro CBCT precision study was performed. Measurement differences ranged from 0.07 to 0.26 mm and occurred because anatomic differences were not considered clinically significant.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…5,13,18 Despite the changes in teeth position due to orthodontic treatment, 8,18 CBCT scans produce a high level of reproducibility, which reasserts its use in orthodontics. 5,17,18 In order to evaluate root length, an in vitro CBCT precision study was performed. Measurement differences ranged from 0.07 to 0.26 mm and occurred because anatomic differences were not considered clinically significant.…”
Section: Discussionmentioning
confidence: 99%
“…13 Computed tomography scans have been regarded as the most precise tool in detecting root resorption. 5,13,[15][16][17][18] Therefore, conebeam computed tomography (CBCT) images showing root resorption may influence orthodontists in either continuing or modifying the treatment plan as needed. 15 The purpose of this prospective study was to compare the magnitude of EARR incisors in patients undergoing the initial phase of orthodontic treatment, with self-ligating and conventional brackets.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, significant effort has been devoted to comparing diagnostic and outcomes measurements taken from CBCT images against measurements taken from conventional 2-D radiographs. There is widespread agreement that CBCT images are better than conventional 2-D lateral cephalographs, 2-10 posterior-anterior cephalographs 11 and panoramic radiographs 12 for landmark identification and measurement accuracy. Only three studies did not validate CBCT image superiority over 2-D lateral cephalograph.…”
Section: Cbct Accuracy and Reliability -Cephalometricsmentioning
confidence: 99%
“…36 Overall, root lengths measured from CBCT images are more accurate than those taken from 2-D images. 12,33,35,[37][38][39][40] EARR studies not only provide valuable clinical information, but several of these studies have tested the accuracy and reliability of measurements taken on different CBCT machines and at different image resolutions, which can vary considerably 33,38,41 or at different voxel sizes. 37,39 Image resolution can be quite different between CBCT machines depending on the sensor used, with relatively low-resolution, largevolume images being generated on 12'' sensors (e.g.…”
Section: Tooth Localizationmentioning
confidence: 99%
See 1 more Smart Citation