2019
DOI: 10.1039/c9ra07106g
|View full text |Cite
|
Sign up to set email alerts
|

Rotary manifold for automating a paper-basedSalmonellaimmunoassay

Abstract: Easy-to-use rotary manifold enables an immunomagnetic separation sandwich immunoassay for foodborne pathogen detection at the point-of-need.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
25
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 33 publications
(25 citation statements)
references
References 53 publications
0
25
0
Order By: Relevance
“…As of March 2020 we did not find any scientific manuscript describing the development of a LFA using solely Fusion5, instead we found references using Fusion5 as part of LF strips or more complex structures. [172][173][174][175][176][177][178][179] Non-conventional materials. Other interesting low cost alternatives to the conventional LFAs membranes, such as cotton threads, cellulose and glass capillaries have been described in the last years.…”
Section: Assembly Of the Lfamentioning
confidence: 99%
“…As of March 2020 we did not find any scientific manuscript describing the development of a LFA using solely Fusion5, instead we found references using Fusion5 as part of LF strips or more complex structures. [172][173][174][175][176][177][178][179] Non-conventional materials. Other interesting low cost alternatives to the conventional LFAs membranes, such as cotton threads, cellulose and glass capillaries have been described in the last years.…”
Section: Assembly Of the Lfamentioning
confidence: 99%
“…A 200 mM HCl with 400 mM Bistris (pH = 6.51) solution was used as the LE, while a 10 mM Tricine with 20 mM Bistris (pH = 7.45) solution was used as the TE . CPR was chosen as the analyte, because it is visible to the naked eye, has an adequate mobility and it is produced by β‐galactosidase when chlorophenol red‐β‐D‐galactopyranoside is used as a substrate to detect, for example, bacteria . A 10 µM CPR concentration was used, which is compatible with real applications .…”
Section: Resultsmentioning
confidence: 99%
“…Images were processed using NIH ImageJ . The original image was split into red, green and blue channels and the inverted green channel intensity was measured in the reservoirs and channel sections to quantify the red color of CPR, as previously described . The corrected green channel values (I G ) were obtained subtracting the inverted green channel value of wet paper to the inverted green channel values in the ITP channel sections.…”
Section: Resultsmentioning
confidence: 99%
“…Thus, the problem of developing microfluidic platforms for the on-site detection of common foodborne pathogens in milk samples has attracted great interest in the recent literature. Typically, these platforms have been designed for the detection of E. coli [ 86 , 90 , 91 , 92 , 93 ], S. aureus [ 94 , 95 , 96 ], Listeria [ 97 , 98 , 99 ], and Salmonella [ 100 , 101 , 102 , 103 , 104 ].…”
Section: Microfluidic Platforms For Milk Sample Analysismentioning
confidence: 99%
“…Many microfluidic devices have been proposed for the detection of Salmonella in milk samples. Generally speaking, these devices use colorimetric, immunoassay (microchip-based, thread-based, rotary paper-based), EC biosensing, fluorescence, and PCR amplification combined with LIF [ 100 , 101 , 102 , 103 , 104 ]. For example, An et al [ 108 ] presented a microfluidic lab-on-a-chip platform in which a microfluidic droplet device was used to encapsulate single Salmonella cells in a growth medium and the encapsulated droplets were then collected.…”
Section: Microfluidic Platforms For Milk Sample Analysismentioning
confidence: 99%